Remote Configuration – INSTALLER LEVEL
Infrared remote configuration
To enter the remote configuration mode in the remote, the DOWN ARROW button must be
depressed with the LOUVER button for 5 continuous seconds while the remote is in Off
mode.
The remote will clear its display. The configuration item will be displayed in the two digit
temperature display and the value of that item will be displayed in the four-digit time display.
The configuration initially displays whatever the previously saved value was, if there is no
previous value, the items will display the default value. The remote will initially display the
configuration item "CH" for remote configuration. In order to store the infrared remote's
value, press the LOUVER button
Infrared OFF mode
Configuration Item
" CH"
" tU"
" rc"
" HR"
" CR"
" CL"
Remote Control Functions
At least for 5
continuos seconds
+
Value
Ab : Both
A : Channel A
b : Channel B
C : Degrees C
F : Degrees F
HP : Normal Operation
CO : Cooling Only
17 – 32 : 17° - 32° C
63 – 90 : 63° - 90° F
17 – 32 : 17° - 32° C
63 – 90 : 63° - 90° F
12 : 12 Hour Standard (AM/PM)
24 : 24 Hour Military
+
.
First item shown
Description
Remote ID selection
Defaults to Ab
Temperature units
Defaults to C
Puts the Remote into Cooling
Mode only
Defaults to HP
Maximum heating setpoint.
Degrees C or F is determined by
"tU" configuration above.
Minimum cooling setpoint.
Degrees C or F is determined by
"tU" configuration above.
Time Format
Defaults to 12