Functions and User Friendly.
Programming [EzSQ: Easy Sequence] function
Inverter control by Built-in
Programming function
Simple sequence operation is realized by downloading to an
inverter the program created by programming soft EzSQ.
It is also possible to automatic speed control according to a load
situation like a swift lift function for crane or a conveyor, and to
operate.
Since an external circuit can be simplified, a control board is
made small and a cost cut can be aimed at.
Password function is added to prevent program information
leaks. This is also useful for unexpected data rewriting or
deletion by operation mistake.
[The example of a use] Example for Rely sequence
Current INV
PB1
PB2
RY1
PB2
PB1
RY2
Operation
circuit
RYA FW
RYB
8
CM1
Current INV
Internal Option
Built-in EMC Filter
Cost and space reduction compared with external EMC Filter.
Reduces electromagnetic noise.
EN61800-3 2nd-Environment
Brake circuit up to 22kW
Cost and Space reduction compared with external Braking
Controller.
SJ700
RY1
T2
RYA
T1
EzSQ
Programming
RY2
T1
RYB
Programming window
T2
Download
PB1
1
PB2
2
CM1
SJ700
Item
Description
Language type
BASIC Like
Supported Device Windows(DOS/V)OS:Windows98SE,Windows2000,WindowsXP)
1,024 steps or 6k byte
Memory area
(Smaller of these)Program is stored in internal of inverter.
Editor(Windows),Display(Windows)
Programming
Grammar check(Windows)
environment
Program download/upload, All clear
Executable format
Interpreter 2.0ms/command (Sub routine supported. 8 nested)
Contact signal/Open collector signal input
(Internal DC24V power supply available)
External digital
Program RUN
contact input
command
General-purpose
External input
input
XA(0) : 0-10V (O terminal)
External analog
XA(1) : 4-20mA (OI terminal)
input
XA(2) : 0-10V (O2 terminal)
General-purpose
Maximum of 8 point(Y(00)-Y(05))
output terminal
YA(0) : Setup for FM terminal is possible.
External output
External analog
YA(1) : Setup for AM terminal is possible.
output
YA(2) : Setup for AMI terminal is possible.
Programmable flow control <Loop,Unconditional jump, conditional jump,
Time control, Sub routine, Others>
Operation command <+,-,,*, /, substitution, mod, abs>
Command
I/O control(Bit input, Word input, Bit output, Word output)
Timer control <on delay, off delay>
Inverter parameter setting
User
U(00)-U(31)/32 point
Timer
UL(00)-UL(03)/4 point
Set frequency
SET-Freq
Acceleration time ACCEL
Deceleration time DECEL
Output frequency, Output current, Rotative direction,
PID feedback, Converted frequency, Output torque,
Monitor
Output voltage, Power, Cumulative RUN time,
Cumulative power-on time, trip
Variable
General-purpose
X(00)-X(07)/8 point
input contact
General-purpose
Y(00)-Y(05)/6 point(1 point is relay output)
output contact
Internal user
UB(00)-UB(07)/8 point
Internal timer
TD(0)-TD(7)/8 point
contact
Inverter input
In a remote operator display code.
and output
*
Windows
is a registered trademark of Microsoft Corporation.U.S.A and other countries.
¨
Example (110HFEF2)
130
120
110
100
90
80
70
60
50
40
30
20
10
0
150k200k
500k
1M
Frequency [Hz]
FW terminal is reserved
Maximum of 8 point(X(00)-X(07))
EN61800-3 2nd Envinment
C3
QP Limit Level
2M
5M 7M 10M
20M 30M
QP: Quasi Peak
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents