Hitachi SJ700 Series Manual page 13

Powerful inverter
Hide thumbs Also See for SJ700 Series:
Table of Contents

Advertisement

Code
Code
Function Name
Function Name
A105
OI-L input start frequency enable
A111
O2-L input active range start frequency
A112
O2-L input active range end frequency
A113
O2-L input active range start voltage
A114
O2-L input active range end voltage
A131
Acceleration curve constants setting
A132
Deceleration curve constants setting
A141
Operation-target frequency selection 1
A142
Operation-target frequency selection 2
A143
Operator selection
A145
Frequency to be added
A146
Sign of the frequency to be added
A150
EL-S-curve acceleration ratio 1
A151
EL-S-curve acceleration ratio 2
A152
EL-S-curve deceleration ratio 1
A153
EL-S-curve deceleration ratio 2
B GROUP: FINE TUNING FUNCTIONS
Code
Function Name
b001
Selection of restart mode
b002
Allowable under-voltage power failure time
b003
Retry wait time before motor restart
b004
Instantaneous power failure/under-voltage trip alarm enable
b005
Number of restarts on power failure/under-voltage trip events
b006
Phase loss detection enable
b007
Restart frequency threshold
b008
Selection of retry after tripping
b009
Selection of retry after undervoltage
b010
Selection of retry count after overvoltage or overcurrent
b011
Retry wait time after tripping
b012
Electronic thermal setting (calculated within the inverter from current output)
b212
Electronic thermal setting (calculated within the inverter from current output), 2nd motor
b312
Electronic thermal setting (calculated within the inverter from current output), 3rd motor
b013
Electronic thermal characteristic
b213
Electronic thermal characteristic, 2nd motor
b313
Electronic thermal characteristic, 3rd motor
b015
Free-setting electronic thermal frequency (1)
b016
Free-setting electronic thermal current (1)
b017
Free-setting electronic thermal frequency (2)
b018
Free-setting electronic thermal current (2)
b019
Free-setting electronic thermal frequency (3)
b020
Free-setting electronic thermal current (3)
b021
Overload restriction operation mode
b022
Overload restriction setting
b023
Deceleration rate at overload restriction
b024
Overload restriction operation mode (2)
b025
Overload restriction setting (2)
b026
Deceleration rate at overload restriction (2)
b027
Overcurrent suppression enable
b028
Active frequency matching, scan start frequency
b029
Active frequency matching, scan-time constant
b030
Active frequency matching, restart frequency select
b031
Software lock mode selection
b034
RUN/ power-on warning time
b035
Rotational direction restriction
b036
Reduced voltage start selection
b037
Function code display restriction
b038
Initial-screen selection
b039
Automatic user-parameter setting function enable
Torque limit selection
b040
b041
Torque limit(1) (Forward-driving in 4-quadrant mode)
b042
Torque limit(2) (Reverse-regenerating in 4-quadrant mode)
b043
Torque limit(3) (Reverse-driving in 4-quadrant mode)
b044
Torque limit(4) (Forward-regenerating in 4-quadrant mode)
b045
Torque limit LADSTOP enable
b046
Reverse RUN protection enable
b050
Controlled deceleration and stop on power loss
b051
DC bus voltage trigger level during power loss
b052
Over-voltage threshold during power loss
b053
Deceleration time setting during power loss
b054
Initial output frequency decrease during power loss
b055
Proportional gain setting for nonstop operation at power loss
Monitored data or setting
Monitored data or setting
00 (external start frequency), 1 (0 Hz)
-400. to -100., -99.9 to 0.00 to 99.99, 100.0 to 400.0 (Hz)
-400. to -100., -99.9 to 0.00 to 99.99, 100.0 to 400.0 (Hz)
-100. to 02 end-frequency rate (%)
"02 start-frequency rate" to 100. (%)
01 (smallest swelling) to 10 (largest swelling)
01 (smallest swelling) to 10 (largest swelling)
00 (digital operator), 01 (keypad potentiometer), 02 (input via O), 03 (input via OI),
04 (external communication), 05 (option 1), 06 (option 2), 07 (pulse-string frequency input)
00 (digital operator), 01 (keypad potentiometer), 02 (input via O), 03 (input via OI),
04 (external communication), 05 (option 1), 06 (option 2), 07 (pulse-string frequency input)
00 (addition: A141 + A142), 01 (subtraction: A141 - A142), 02 (multiplication: A141 x A142)
0.00 to 99.99, 100.0 to 400.0 (Hz)
00 (frequency command + A145), 01 (frequency command - A145)
0. to 50. (%)
0. to 50. (%)
0. to 50. (%)
0. to 50. (%)
Monitored data or setting
00 (tripping), 01 (starting with 0 Hz), 02 (starting with matching frequency), 03 (tripping after
deceleration and stopping with matching frequency), 04 (restarting with active matching frequency)
0.3 to 25.0 (s)
0.3 to 100.0 (s)
00 (disabling), 01 (enabling), 02 (disabling during stopping and decelerating to stop)
00 (16 times), 01 (unlimited)
00 (disabling), 01 (enabling)
0.00 to 99.99, 100.0 to 400.0 (Hz)
00 (tripping), 01 (starting with 0 Hz), 02 (starting with matching frequency), 03 (tripping after
deceleration and stopping with matching frequency), 04 (restarting with active matching frequency)
00 (16 times), 01 (unlimited)
1 to 3 (times)
0.3 to 100.0 (s)
0.20 x "rated current" to 1.00 x "rated current" (A)
0.20 x "rated current" to 1.00 x "rated current" (A)
0.20 x "rated current" to 1.00 x "rated current" (A)
00 (reduced-torque characteristic), 01 (constant-torque characteristic), 02 (free setting)
00 (reduced-torque characteristic), 01 (constant-torque characteristic), 02 (free setting)
00 (reduced-torque characteristic), 01 (constant-torque characteristic), 02 (free setting)
0. to 400. (Hz)
0.00 to rated current (A)
0. to 400. (Hz)
0.00 to rated current (A)
0. to 400. (Hz)
0.00 to rated current (A)
00 (disabling), 01 (enabling during acceleration and deceleration), 02 (enabling during constant
speed), 03 (enabling during acceleration and deceleration (increasing the speed during regeneration))
0.20 x "rated current" to 1.00 x "rated current" (A)
0.10 to 30.00 (s)
00 (disabling), 01 (enabling during acceleration and deceleration), 02 (enabling during constant speed),
03 (enabling during acceleration and deceleration (increasing the speed during regeneration))
0.20 x "rated current" to 2.00 x "rated current" (A)
0.10 to 30.00 (s)
00 (disabling), 01 (enabling)
0.20 x "rated current" to 2.00 x "rated current" (A)
0.10 to 30.00 (s)
00 (frequency at the last shutoff), 01 (maximum frequency), 02 (set frequency)
00 (disabling change of data other than "b031" when SFT is on), 01 (disabling change
of data other than "b031" and frequency settings when SFT is on), 02 (disabling change
of data other than "b031"), 03 (disabling change of data other than "b031" and
frequency settings), 10 (enabling data changes during operation)
0. to 9999. (0 to 99990), 1000 to 6553 (10000 to 655300) (hr)
00 (enabling both forward and reverse rotations), 01 (enabling only forward rotation), 02 (enabling only reverse rotation)
0 (minimum reduced voltage start time) to 255 (maximum reduced voltage start time)
00 (full display), 01 (function-specific display), 02 (user setting), 03 (data comparison display), 04 (basic display)
00 (screen displayed when the STR key was pressed last), 01 (d001), 02 (d002), 03 (d003), 04 (d007), 05 (F001)
00 (disabling), 01 (enabling)
00 (quadrant-specific setting), 01 (switching by terminal), 02 (analog input), 03 (option 1), 04 (option 2)
0. to 200. (%), no (disabling torque limitation)
0. to 200. (%), no (disabling torque limitation)
0. to 200. (%), no (disabling torque limitation)
0. to 200. (%), no (disabling torque limitation)
00 (disabling), 01 (enabling)
00 (disabling), 01 (enabling)
00 (disabling), 01 (enabling)
0.0 to 999.9, 1000. (V)
0.0 to 999.9, 1000. (V)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
0.00 to 10.00 (Hz)
0.00 to 2.55
×
[◯
= Allowed
= Not permitted
Setting
Setting
Change
Change
Default Setting
Default Setting
during operation
during operation
during operation
during operation
-FE(CE)
-FE(CE) -FU(UL)
-FU(UL)
(allowed or not)
(allowed or not)
(allowed or not)
(allowed or not)
00
00
×
0.00
0.00
×
0.00
0.00
×
-100.
-100.
×
100.
100.
×
02
02
×
02
02
×
02
02
×
03
03
×
00
00
×
0.00
0.00
×
00
00
×
25.
25.
×
×
25.
25.
×
×
25.
25.
×
×
25.
25.
×
×
×
[◯
= Allowed
= Not permitted
Setting
Change
Default Setting
during operation
during operation
-FE(CE) -FU(UL)
(allowed or not)
(allowed or not)
00
00
×
1.0
1.0
×
1.0
1.0
×
00
00
×
00
00
×
00
00
×
0.00
0.00
×
00
00
×
00
00
×
3
3
×
1.0
1.0
×
×
Rated current of
×
inverterx 1..0
×
01
01
×
01
01
×
01
01
×
0.
0.
×
0.0
0.0
×
0.
0.
×
0.0
0.0
×
0.
0.
×
0.0
0.0
×
01
01
×
×
Rated current x 1.50
1.00
1.00
×
01
01
×
×
Rated current x 1.50
1.00
1.00
×
01
01
×
×
Rated current of inverterx 1..0
0.50
0.50
×
00
00
×
01
01
×
0.
0.
×
00
00
×
×
06
06
×
04
04
×
01
01
×
00
00
×
00
00
×
150.
150.
×
150.
150.
×
150.
150.
×
150.
150.
×
00
00
×
00
00
×
00
00
×
×
0.0
0.0
×
×
0.0
0.0
×
×
1.00
1.00
×
×
0.00
0.00
×
×
0.20
0.20
12