DIP Switch Configuration
All versions of the CabSafe controller are configured
using DIP switches. The switch settings are described
in the following paragraph.
Switches should be
configured when power is off on the CabSafe Controller.
ON = 1
OFF = 0
DIP SW 1 & 2 – CabSafe 3D Location
The CabSafe 3D location is the position of the sensor as
you look into the elevator cab from the landing side. For
side-opening applications, the CabSafe 3D must be
mounted on the same side as the slam post / strike jamb.
Function
No function
CabSafe 3D mounted on left
CabSafe 3D mounted on right
CabSafe 3D mounted in center
Distance "D" as shown below is 240 ± 10 mm (9.45 ± 0.4
inches).
The above figure shows a "Sensor Mounted on Right."
The above figure shows a "Sensor Mounted on Left."
DIP SW 3 & 4 – Door Closed Detection
Normally, the light curtain is able to detect when the
doors have reached a point when the CabSafe 3D can
be rendered inoperative. When the light curtain does not
move with the door(s), an external signal is used to
render the CabSafe 3D inoperative. The external signal
should transition less than 450 mm (18 inches) from full
close. For additional information, see operating manual.
Function
No function
Via Light Curtain
Via External Signal
DIP SW 5 – 8: Sensor Mounting Height
Select based on the mounting height of the CabSafe 3D.
Function
No function
DIP 1
DIP 2
6.67 – 7.5 ft
0
0
> 7.5 to 8.5 ft
1
0
> 8.5 to 9 ft
0
1
> 9 to 10 ft
1
1
DIP SW 9: 2D/3D Select
To fulfill ANSI A17.1-2019 / CSA B44-19, both the
CabSafe 2D and CabSafe 3D must be active. If DIP9 is
configured as 2D Only, the CabSafe 3D sensor must be
disconnected from the CabSafe Controller.
2D and 3D Both Active
2D Only
DIP SW 10: Output Logic Selector
This configuration changes the polarity of the output.
Standard
Inverted
116 122 (210504A) Quick Start Guide CabSafe
DIP 3
DIP 4
0
1
0
DIP 5
DIP 6
DIP 7
0
0
0
1
0
0
0
1
0
0
0
1
0
0
0
Function
DIP 9
0
1
(3D must be disconnected)
Function
DIP 10
0
1
CabSafe 100 Solid-state Output Variant
0
0
1
CabSafe 100/200 Relay Output Variant
DIP SW 11: 3D Frequency Selector
This setting is used to prevent interference between
DIP 8
CabSafe systems when elevators face one another.
0
0
Function
0
Frequency Range Group A
0
Frequency Range Group B
1
DIP SW 12: Reserved for future use.
An online support and troubleshooting
tool is available to assist with
installation and troubleshooting.
Scan the QR code This link is also
available at
www.cedes.com
Product Listing – CabSafe.
CEDES Corporation of America
Telephone: +1 612.424.8400
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.