BELL SYSTEM PRACTICES
Plant Series
1.
GENERAL
1.01
This section p r o v i d e s m a i n t e n a n c e and
connection i n f o r m a t i o n for the 2565LK
telephone s e t s .
Maintenance information was
formerly found in Section 502-525-125.
information was formerly found in Section 502-525-437
which is hereby canceled.
2.
MAINTENANCE
Replaceable Components
2.01
Field replaceable items are listed under
Ordering Guide in the appropriate Reference
section in Division 502.
Loose
Card
Retainers
2.02
Current production sets are equipped with
P-25E803 and P-269561 card retainers, which
cannot be adjusted.
2.03
If P-25E785 (MD) card retainer becomes so
loose on the faceplate that the number card
or designation strip slips, they can be tightened
as follows:
(1) Remove faceplate from set.
(2) Remove card retainer from faceplate.
(3) Bend the four arms of the retainer so that
more pressure will be applied to the number
card and designation strip.
be made approximately 1/2-inch in from the tabs
on the ends of the a r m s and in the opposite
direction from the factory bent tabs.
(4) Install the card retainer on the faceplate
and insert the number card and designation
strip.
(5) Install faceplate on telephone set.
SERVICE
2565LK TELEPHONE SETS
Connection
The bends should
(c) American Telephone and Telegraph Company. 1970
Printed in U.S.A.
Note:
If adjusting the arms of the retainer
does not result in sufficient holding power,
replace the card retainer.
Housing
2.04
When removing or replacing housing, guide
lower front of housing over pushbuttons.
On sets equipped with exclusion, pull exclusion
plunger up to its operated position before removing
housing.
Plunger should also be in upper position
when replacing housing.
operate plunger several times to insure proper
operation.
Lamps
and
Pushbuttons
2.05
R e p l a c e c r a c k e d p u s h b u t t o n s or collar
assemblies.
Plastic parts may be cleaned
with a w a t e r dampened cloth.
SOLVENTS.
Lamps should be near associated
p u s h b u t t o n with c o n t a c t s u r f a c e s aligned for
maximum illumination.
2.06
To replace defective lamp.
(1) Remove button and collar assembly.
(2) Gently pry lamp from socket with KS-6320
orange stick.
(3) Replace lamp, m a k i n g sure t h a t contact
surface on lamp and socket meet.
(4) Replace button and collar assembly.
Keys—589-Type
2.07
Key contacts may be cleaned using a 265C
tool, or adjusted using a 363 tool.
adjusting springs:
(a) There should be a minimum clearance of
1/64-inch between contact springs and those
parts of the key which do not make contact.
SECTION 502-543-406
Issue 1, May 1970
AT&TCo Standard
With housing in place,
DO NOT USE
When
Page 1