3. Installation of outdoor unit
3.6 Clearance space
3.6.1 Clearance around outdoor unit
• Ensure that the space around the back is
more than 300 mm on the opposite to the
PCB side and secure 600 mm space near
the compressor and PCB side of the air
conditioner for service.
• Install the unit so that its discharge port faces
to the wall of the building. Keep a distance
500mm or more between the unit and the wall
surface.
• Supposing the wind direction during the oper-
ation season of the air conditioner, install the
unit so that the discharge port is set at right
angle to the wind direction.
300 mm or more
300 mm or more
h Outdoor unit is representative. Actual appearance of outdoor unit
may be different but clearances will stay the same.
Air inlet grille
Turn the air outlet side toward the build-
ing's wall, fence or windbreak screen.
h Outdoor unit is representative. Actual appearance of outdoor unit may be
different but clearances will stay the same.
300 mm
or more
100 mm
100 mm
300 mm
F e
or more
or more
or more
n c
o b
e o
s t a
r
c l e
s
600 mm or more
(Service space)
Strong
wind
Blown
air
500
Set the otlet side at a rignt angle
to the direction of the wind.
Heat pump
50Hz/R410A
Strong
wind
_ 48