can be widely used for liquid level measurement and control in fields of
petroleum, chemi-industry, medicine, metallurgy, power station, mining,
urban water supply, drainage and hydrology survey, etc.
3 Specification
Pressure Range: 10m, 20m, 50m, 100m,200mH
O
2
Overpressure: 1.5 times FS
Accuracy: ±0.5%FS
Stability: Range>20mH
O, ±0.2%FS/year
2
Range≤20mH
O,
20mmH
O
2
2
Operation temp.: -10℃~70℃
Storage Temp.: -20℃~85℃
Power Supply: 11V~28V DC
Output Signal: 4mA~20mA DC(two wire)
Load (Ω): ≤ (U-11)/0.02(Ω)
Insulated Resistance: 500VDC,20MΩ
4 Construction Material
Housing: 1Cr18Ni9Ti
Cap: Black Nylon
O- ring: Viton
Rubber casing: Chloroprene Rubber
Cable: Φ7.5mm PE cable with vented tube
Diaphragm: SS 316L
Connection Box: Cast aluminium (ZL102)/ PBT
5 Outline Dimension of transmitter
5.1 The outline dimension is showed as Figure 1:(unit:mm)