Haier U Series Service Manual page 13

Dc inverter wall mounted type
Table of Contents

Advertisement

PCB1: control PCB
1
CN2 connector for electronic inflated valve
2
CN4/CN8connector for CN1/CN2 in PCB2 for supply 310V
3
CN19/CN21/CN22/CN20 connector for suction/defrost/ambient/compressor sensor
4
CN3 connector for CN10 in PCB3
5
CN14 connector for 4-way valve
6
CN18/25/26 connector for fan motor
7
CN9 connector for N(IN) in PCB3
8
CN6 is L wiring
9
CN7 is N wiring
10
CN10 is GROND wiring
11
CN10` is linking cable between the indoor and outdoor
PCB2:
12
CN1 connector for CN4 in PCB1
13
CN2 connector for CN8 in PCB1
14
CN3 connector for P+ in PCB3
15
CN4 connector for N- in PCB3
PCB3:
16
U/V/W connector for black/white/red wire of compressor
17
connector for CN11 in PCB1
18
CN5 connector for CN16 in PCB1
19
P/N is how to connect referring to PCB2
20
LX1/LX2 connector for inductance
21
P OUT+ and N OUT- are how to connect referring to PCB2
22
L IN and N IN are how to connect referring to PCB1
HSU-09,12H03/U(DBPZXF)
PCB1
CN1
SW1
PCB2
10
Connector wiring Diagram
Domestic Air Conditioner

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents