Operation; Installation Precautions; Necessary Equipment - diagral DD400 Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7
FIG. A
The drawing in figure A shows the DIAGRAL technical protection and
associated devices for efficient protection of your home.
The DD400 flooding detector indicates water levels in excess of
2 mm.
The DD410 deep freezer failure detector indicates temperatures in
excess of -12°C.
The DD420 EDF electricity failure detector indicates power cuts of
more than 18 min ± 20% (short cut) or 5 hours ± 20% (long cut).
The DD430 minimum temperature detector indicates temperatures of
less than +5°C.
Combined with a CB950 control panel, the DIAGRAL domestic dama-
ge detectors (on the left) operate all round the clock whether or not the
GB
break-in protection is working.
Should a problem occur on a piece of domestic equipment, the detec-
tor will immediately inform your control panel by radio. The control
Dual Frequency radio transmission
Installation radio code
Each detector consists of a probe which is connected to a transmission
box via a 1.20 m long cable
Test key designed to:
- check battery state
- check the radio link
- arm/disarm the domestic damage detector transmissions
green light indicator confirming the detector is armed (rapid flashing)
DIAGRAL offers phone assistance. Our technicians are at your dispo-
sal to answer any questions you may have concerning the operation of
our products.
Place the transmission box:
high up (at least 80 cm) to simplify radio transmission
tighten the probe connection flat cable.
A drill with a 6 mm bit
A 3 mm flat screwdriver
1

OPERATION

2
FEATURES
3
WARNING
4

INSTALLATION PRECAUTIONS

5

NECESSARY EQUIPMENT

6
panel stores the message and warns you of the problem by 4 audible
bips sent out at 90 second intervals. The dialer automatically alerts your
surveillance centre or neighbours. The detector emits 4 audible bips at
90 second intervals to simplify location of the problem.
On return home, you can consult your control panel by pressing OFF on
your remote control or keypad.
A series of audible signals and a flashing light on the control panel
confirm that the problem has been memorised.
The alarm memory will be deleted the next time the break-in protection
is armed.
DIAGRAL also offers a DD350 smoke detector. In the event of a fire, the
control panel, the alarm siren, the telephone dialer and the control recei-
ver are triggered.
The detectors are compatible with the DIAGRAL Dual Frequency
control panels.
red light indicator confirming:
- battery state OK
- the detector is disarmed (rapid flashing)
- programming is OK (5 sec fixed lighting)
- a programming error (rapid flashing)
Round the clock tamper-proof function against opening
Power supply by 9 V alkaline battery (supplied)
2 years battery life
If you have any comments to help us improve our guides or products,
please do not hesitate to contact us in writing, indicating the purchase
date of your equipment.
Do not place the transmission box:
directly on a metal surface.
The bag of accessories (supplied)
The 9V battery (supplied)
®

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dd410Dd430Dd420

Table of Contents