Rockwell Automation Allen-Bradley Bulletin 1609 Installation Instructions Manual

Rockwell Automation Allen-Bradley Bulletin 1609 Installation Instructions Manual

Industrial uninterruptible power supply
Hide thumbs Also See for Allen-Bradley Bulletin 1609:

Advertisement

Quick Links

Installation Instructions
Bulletin 1609 Industrial Uninterruptible Power Supply
(Cat 1609-D)
ATTENTION: Please read and save these instructions. This manual contains important instructions for the Bulletin 1609 Uninterrupt-
ible Power Supply. Follow these instructions during the unpacking, installation and maintenance of the UPS. If you have a problem
with the UPS, please refer to this manual and the User Manual trouble shooting section before calling Technical Services.
Contents for UPS Include:
• Installation Instruction
•1609-D
•USB Cable
•CD
•2 Battery Jumper Wires (inside the battery
compartment)
•Battery Harness (inside the battery compartment)
Note: Batteries are not included with the UPS and 1609-EXBAT.
Additional Resources
1. Go to http://www.rockwellautomation.com/literature
2.
Go to Search, select Publication Number.
3. Type the Publication Number in the search box and press enter.
1609-IN014 (1609-SPD Installation Instructions)
1609-IN015 (1609-ENET Installation Instructions)
1609-UM007 (1609 UPS Management Software User Manual)
1609-UM008 (1609 Network Management Card User Manual)
1609-UM009 (1609 UPS User Manual)
Install the 1609 UPS in the Appropriate Environment
Do not operate the UPS where there is excessive dust or the temperature or humidity is outside the
speci ed limits. The maximum ambient temperature is 40 degree Celsius using the 1609-SBAT or 50 degree
Celsius using the 1609-HBAT. The maximum humidity specification is 95% RH (Non-condensing).
Contents for 1609-EXBAT Include:
•Installation Instruction
•1609-EXBAT
•Connector Cover
•2 Screws
•4 Battery Jumper Wires (inside the battery
compartment)
•Battery Harness (inside the battery compartment)

Advertisement

Table of Contents
loading

Summary of Contents for Rockwell Automation Allen-Bradley Bulletin 1609

  • Page 1 Installation Instructions Bulletin 1609 Industrial Uninterruptible Power Supply (Cat 1609-D) ATTENTION: Please read and save these instructions. This manual contains important instructions for the Bulletin 1609 Uninterrupt- ible Power Supply. Follow these instructions during the unpacking, installation and maintenance of the UPS. If you have a problem with the UPS, please refer to this manual and the User Manual trouble shooting section before calling Technical Services.
  • Page 2 Bulletin 1609 Industrial Uninterruptible Power Supply Batteries Wiring and Installation Instruction for the UPS Only use battery wires that have been provided with the UPS. Warning: Do not service the 1609-SPD without disconnecting the power sources due to electric shock harzard for risk of severe injury or death.
  • Page 3 Bulletin 1609 Industrial Uninterruptible Power Supply 1609-EXBAT Batteries Wiring and Installation Instruction Only Only use battery wires that have been provided with the 1609-EXBAT. Warning: A disconnect switch shall be provided by others for DC output circuit. To reduce the risk of re, connect only to a circuit provided with branch circuit overcurrent protection for 35 amperes rating in accordance with the National Electric Code, ANSI/NFPA 70“...
  • Page 4: Mount The Ups

    Bulletin 1609 Industrial Uninterruptible Power Supply 5. Insert the batteries into the battery compartment in the orientation as shown in the photo below. Cut-Out Hole Connector Retainer 6. Open the white connector retainer and connect the two cables together as shown in the photo below. 7.
  • Page 5: Hardwire Ups

    Bulletin 1609 Industrial Uninterruptible Power Supply Hardwire UPS Wiring of the UPS should be performed by a qualified electrician using the appropriate wire gauges. Selection of Cables: AC Main Input / Output Wiring for UPS: Item Speci cation Wire size 14 AWG Minimum temperature 75°C...
  • Page 6 Recommended Battery for use with the UPS and External Battery Cabinet Rockwell Automation battery catalog numbers 1609-SBAT and 1609-HBAT consists of the battery manufacturers listed below:...
  • Page 7: Dry I/O Contacts

    Bulletin 1609 Industrial Uninterruptible Power Supply Dry I/O Contacts There is one Remote Enable/Disable Switch connection and 3 Dry I/O Contacts available on the front of the UPS. Do not apply external power to the Remote Enable/Disable Switch; however, the 3 sets of Dry Contacts required external power supplies (Contacts Rating is 1A/24 Vdc).
  • Page 8: Display Led Indicators

    1. Review the problems discussed in the troubleshooting section of the 1609 UPS User Manual to eliminate common problems. 2. If the problem persists, contact Rockwell Automation Customer Support at 440-646-5800. 3. Pack the UPS in its original packaging. . Pack the UPS properly to avoid damage in transit. Never use Styrofoam beads for packaging.

This manual is also suitable for:

Allen-bradley bulletin 1609-d

Table of Contents