System HP
Conbination HP
50
24
14
52
24
14
54
20
20
56
24
20
58
24
20
60
24
24
62
24
24
64
24
20
66
24
22
68
24
24
70
24
24
72
24
24
74
24
24
76
24
24
78
24
20
80
24
24
82
24
24
84
24
24
86
24
24
88
24
24
90
24
24
92
24
24
94
24
24
96
24
24
98
24
24
100
24
24
102
24
24
104
24
24
106
24
24
108
24
24
110
24
24
112
24
24
114
24
24
116
24
24
118
24
24
120
24
24
Table 2
Liquid pipe dia. (mm)
Additional refrigerant amount per 1 m
liquid pipe (kg/m)
43-EN
Compensation by System HP (kg)
12
-
-
14
-
-
14
-
-
12
-
-
14
-
-
12
-
-
14
-
-
20
-
-
20
-
-
20
-
-
22
-
-
24
-
-
14
12
-
14
14
-
20
14
-
20
12
-
20
14
-
24
12
-
24
14
-
20
20
-
22
20
-
24
20
-
24
22
-
24
24
-
24
14
12
24
14
14
20
20
14
24
20
12
24
20
14
24
24
12
24
24
14
24
20
20
24
22
20
24
24
20
24
24
22
24
24
24
6.4
9.5
12.7
15.9
19.1
0.025
0.055
0.105
0.160
0.250
Table 3-1
10.1
Corrective amount of refrigerant varies according to indoor unit capacity rank.
10.1
Indoor unit Capacity
rank
10.3
Capacity code
11.8
(Equivalent to HP)
11.8
Corrective amount of
13.3
refrigerant (kg)
13.3
• If the Fresh Air Intake Indoor Unit (MMD-UP
13.5
Fresh Air Intake Indoor Unit is 0 Kg.
14.5
15.0
Table 3-2
16.0
Corrective amount of refrigerant varies for DX Coil Interface
16.5
Capacity code
15.6
(Equivalent to HP)
15.6
Corrective amount of
15.8
refrigerant (kg)
17.3
17.3
Table 3-3
18.8
Corrective amount of refrigerant varies for Hot Water Module
18.8
Indoor unit Capacity rank
19.0
Capacity code (Equivalent to HP)
20.0
Corrective amount of refrigerant (kg)
20.5
21.5
Table 3-4
22.0
Corrective amount of refrigerant varies for (MMU-UP
21.1
Indoor unit capacity rank
21.1
Capacity code (Equivalent to HP)
21.3
Corrective amount of refrigerant (kg)
22.8
22.8
Charging of refrigerant
• Keeping the valve of the outdoor unit closed, be sure to charge the liquid refrigerant into the service port at the
24.3
liquid side.
24.3
• If the specified amount of refrigerant cannot be charged, fully open the valves of the outdoor unit at liquid and
24.5
gas sides, operate the air conditioner in COOL mode, and then charge refrigerant into service port at the gas
25.5
side. In this time, choke the refrigerant slightly by operating the valve of the canister to charge liquid refrigerant.
• The liquid refrigerant may be charged suddenly, therefore be sure to charge refrigerant gradually.
26.0
27.0
Table 4
27.5
Corrective amount of refrigerant varies according to the outdoor unit diversity
Diversity D (%)
22.2
25.4
50% ≤ D < 60%
0.350
0.470
60% ≤ D < 70%
70% ≤ D < 80%
80% ≤ D < 90%
90% ≤ D < 95%
95%≤ D
– 22 –
003 005 007 008 009 010 012 014 015 018 020 024 027 030 036 048 056 072 096
0.3
0.6
0.8
0.9
1
1.1 1.25 1.5
1.7
2
2.25 2.5
0.2
HFP
) is connected, the correction amount refrigerant for
8
10
16
18
20
32
36
40
48
54
60
1.4 1.8 2.9 3.2 3.6 5.8 6.5 7.2 8.6 9.7 10.8
024
048
2.5
5
0.2
H-E) High Efficiency 4 way cassette
009
012
015
018
024
1
1.25
1.7
2
2.5
0.2
Corrective amount
of refrigerant (kg)
-2.5
-2.0
-1.5
-1.0
-0.5
0
3
3.2
4
5
6
8
10
0.4
0.6
1.0
027
030
036
048
056
3
3.2
4
5
6
0.6
EN
44-EN