Download Print this page

Thermistor Assy - Daikin Si001554EC Service Manual

Advertisement

Thermistor ASSY

4. Thermistor ASSY
Warning
 Be sure to wait for 10 minutes or more after turning off all power supplies before
Step
1
Remove the screw.
2
Slide the stop valve
cover downward and
remove it.
3
Remove the 2 screws
and lift up the protection
plate to remove it.
10
disassembling work.
Procedure
Stop valve
cover
(R20843)
 When reassembling, make
sure to fit the 4 hooks.
Hook
(R21630)
 When reassembling, make
sure to fit the 2 hooks.
Protection
plate
(R21631)
Si001554EC
Points
Hook
(R21868)
Removal Procedure