Download Print this page

Pre-Operation Leak Testing - BORETTI Bernini Use And Care Manual

Advertisement

GENERAL INFORMATION
Although all gas connections on the grill are leak tested prior to shipment, a complete gas tightness check
must be performed at the installation site due to possible shifting during shipment, installation or excessive
pressure unknowingly being applied to the unit. Periodically check the whole system for leaks and
immediately check the system if the smell of gas is detected.
BEFORE TESTING
• DO NOT smoke while leak testing.
• Extinguish all open flames.
• Never leak test with an open flame.
• Mix a solution of equal parts mild detergent or liquid soap and water.
TESTING
1. Turn off the burner control knobs.
2. Turn the top knob of the fuel supply cylinder counter-clockwise (right to left) two (2) rotations to open.
3. Apply the soap solution to connections of the fuel supply assembly. If no soap bubbles appear, there is no
gas leak. If bubbles form at the connections, a leak is detected. If a leak is detected, immediately turn off
the gas supply, tighten any leaking fittings, turn gas ON, and repeat steps 1 - 3.
4. Turn off the knob on the fuel supply cylinder.
5. Turn on the burner control knobs for a moment to release the pressure in the hose, then turn the control
knobs back off.
6. Wash off soapy solution with cold water and towel dry.
Check all gas supply fittings before each use and each time the gas supply cylinder is connected to the
regulator. Have a qualified service technician leak test the grill any time a part of the gas system is replaced.
It is also recommended to perform a leak test a least once a year whether or not the L.P. gas supply cylinder
has been disconnected.
NOTE: When leak testing this appliance, make sure to test and tighten all loose connections,
including the side burner. A slight leak in the system can result in a low flame, or hazardous
condition. Most L.P. gas tanks now come equipped with a leak detector mechanism internal
to the tank, when gas is allowed to escape rapidly, it shuts of the gas supply. a leak may
significantly reduce the gas flow making the grill difficult to light or causing low flames.
NOTE: If you cannot stop a gas leak turn off the gas supply and call your local gas supplier or
the dealer you purchased the appliance from. If necessary, replace the faulty part with the
manufacturer's recommended replacement part. A slight leak could cause a fire.

Pre-Operation Leak Testing

Advertisement

loading