Technical Data; Service / Warranty; Warranty Statement - Gardena AquaClean 24/18V P4A Operator's Manual

Battery medium pressure washer
Hide thumbs Also See for AquaClean 24/18V P4A:
Table of Contents

Advertisement

Problem
Possible Cause
Washer does not start
Water has entered the battery. v Allow the battery to dry in
or stops.
(Wp)
Error-LED
is illuminated
There are drops of water or
red [ Fig. O4 ]
moisture between the battery
contacts on the washer.
Engine is blocked.
Nozzle partially or fully
clogged.
Washer does not start
Product is defective.
or stops.
(Wp)
Error-LED
is flashing red
[ Fig. O4 ]
Washer does not start
Battery is not put completely
or stops.
into the battery holder.
(Wp)
Error-LED
is not
illuminated [ Fig. O4 ]
Battery is defective.
Product is defective.
Charging is not possible.
The battery is not connected
(Lc)
Battery charge indicator
(correctly).
is continuously illuminated
Battery contacts are dirty.
[ Fig. O3 ]
Battery temperature is out-
side the permissible charging
temperature range.
Battery is defective.
(Lc)
Battery charge indicator 
Mains plug of the charger is
is not illuminated [ Fig. O3 ]
not (correctly) plugged in.
Socket outlet, mains cable or
charger is defective.
NOTE: For any other malfunctions please contact the GARDENA service depart-
ment. Repairs must only be done by GARDENA service departments or specialist
dealers approved by GARDENA.

7. TECHNICAL DATA

Battery Medium Pressure
Unit
Washer
Rated pressure /
MPa
Max. pressure
Max. supply pressure
MPa
Suction hose length
m
Max. suction head
m
Max. Running times
(2.5Ah battery):
Soft-Clean-Mode high
min.
Soft-Clean-Mode soft
min.
Soft-Clean-Mode ultra soft
min.
Max. Flow rate:
Soft-Clean-Mode high
l/h
Soft-Clean-Mode soft
l/h
Soft-Clean-Mode ultra soft
l/h
Max. Pressure:
Soft-Clean-Mode high
bar
Soft-Clean-Mode soft
bar
Soft-Clean-Mode ultra soft
bar
Weight with short lance
kg
(without Battery)
Sound pressure level L
1)
dB (A)
pA
Uncertainty k
pA
Sound power level L
:
2)
WA
measured
dB (A)
Uncertainty k
WA
Hand / arm vibration a
1)
m/s
vhw
2
Uncertainty k
vhw
Measuring process complying with:
EN 60335-2-54
1)
Remedy
a protected place.
v Remove the water drops /
moisture with a dry cloth.
v Contact the GARDENA
Service.
v Clean the nozzle, e. g. using
a pin / needle or a piece of
wire.
v Contact the GARDENA
Service.
v Put the battery completely
into the battery holder until
it audibly engages.
v Replace the battery.
v Contact the GARDENA
Service.
v Connect the battery to
charger correctly.
v Clean the battery contacts
(e. g. by connecting and
disconnecting the battery
several times. Replace the
battery if necessary.
v Wait until the battery
tem perature is between
0 °C – + 45 °C again.
v Replace the battery.
v Insert the mains plug into the
mains socket (completely).
v Check the mains voltage.
Let the charger be checked
if necessary by an author-
ised specialist dealer or the
GARDENA Service.
Value (Art. 14800)
2.4
0.6
5
2
15
19
38
250
200
100
24
14
9
1.5
68
3
83
3
2.8
1.5
EN 60335-2-79
2)
NOTE: The stated vibration emission value has been measured according to
a standardised test procedure and can be used for comparison of one electric
power tool with another. It can also be used for preliminary evaluation of expo-
sure. The vibration emission value can vary during actual use of the electric power tool.
System Battery
Unit
PBA 18V 2.5Ah W-B
Battery voltage
V (DC)
Battery capacity
Ah
Number of cells (Li-Ion)
Appropriate POWER FOR ALL system Battery Chargers: AL 18..CV.
Battery Charger
Unit
AL 1810 CV P4A
Mains voltage
V (AC)
Mains frequency
Hz
Rated power
W
Battery charging voltage
V (DC)
Max. battery charging
mA
current
Battery charging time
80 % / 97 – 100 % (approx.)
PBA 18V 2.0Ah W-B
min.
PBA 18V 2.5Ah W-B
min.
PBA 18V 4.0Ah W-C
min.
Permitted charging
°C
temperature range
Weight according to
kg
EPTA-Procedure 01:2014
Protection class
Appropriate POWER FOR ALL system Batteries: PBA 18V.
8. ACCESSORIES
GARDENA Rotating Nozzle
For particularly stubborn soiling (moss or weathered
AquaClean Li
surfaces).
GARDENA System Battery
Battery for additional duration or for replacement.
PBA 18V/45 P4A
PBA 18V/72 P4A
GARDENA Battery Quick
Charger for fast charging the POWER FOR ALL
Charger AL 1830 CV P4A
system Batteries PBA 18V..W-..

9. SERVICE / WARRANTY

Service:
Please contact the address on the back page.

Warranty statement:

In the event of a warranty claim, no charge is levied to you for the services
provided.
GARDENA Manufacturing GmbH grants a warranty for all original
GARDENA new products for two years from the date of original pur-
chase from the retailer, provided that the devices have been for private
use only. This manufacturer's warranty does not apply to products
acquired second hand. This warranty includes all significant defects of
the product that can be proved to be material or manufacturing faults.
This war ranty is fulfilled by supplying a fully functional replacement
product or by repairing the faulty product sent to us free of charge;
we reserve the right to choose between these options. This service
is subject to the following provisions:
• The product has been used for its intended purpose as per the
recommendations in the operating instructions.
• Neither the purchaser nor a third party has attempted to open or
repair the product.
• Only Original GARDENA replacement parts and wear parts have
been used for operation.
• Presentation of the receipt.
Normal wear and tear of parts and components (such as blades, blade fix-
ing parts, turbines, light bulbs, V-belts / toothed belts, impellers, air filters,
spark plugs), visual changes, wear parts and consumables are excluded
from the warranty.
Value (Art. 14903)
18
2.5
5
Value (Art. 14900)
220 – 240
50 – 60
26
18
1000
96 / 124
120 / 154
192 / 244
0 – 45
0.17
/ II
Art. 9345
Art. 14903
Art. 14905
Art. 14901
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

14800

Table of Contents