Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
HP Manuals
Control Unit
3484A
Operating and service manual
HP 3484A Operating And Service Manual page 38
Multifunction unit
Hide thumbs
1
2
3
4
Table Of Contents
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
page
of
98
Go
/
98
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
Section
V
DC STANDARD/DIFFERE
NTIAL
VOLTMETER
hp
7408
®
3484A
•
B 30376
OUT
P
UT
CAB LE
hp
110558
Model
3484A
DIGITAL VOLTMETER
hp
3480A
MULTIFUNCTION
@
@ Qi
@
UNIT
hp
3484A
0
@)
@
@
O.
I
F
Figure 5-2.
lnput
Resistance
Check.
f.
Connect de standard
output
to
3484A
input.
Set
de
standard output
to .000000
V.
If 3480A/B
display
indicates
an
offset,
this
must
be
taken into
consideration
when
checking
3484A accuracy
on
the
100
mV range
.
If
-hp-
Model
740B
is being
used
as
de standard,
adjust
740B
ZERO
control
to
return
3480A/B
display
to
zero.
g. Se
t
de
s
tand ard
output
to
+ .100000 V
(+ 100.00
mV).
3480A/B
display
should
be
+ 99 .97
mV
to+
100.03
mV.
h
. Reverse
polarity
of
standard output.
Display
should
be
-
99.97 mV
to - 100.03
mV.
i.
Set de standard
output
to
positive
and
negative
voltages
listed in Table
5-2,
setting 3484A RANGE
switch to
range
.shown
for
each
voltage. Display
should
be
within limits
indicated in
each case.
j
. Repeat
Steps
g
through
i with
line voltages of
103
V
and 127
V
(or
207
V
and
253 V).
5-5.
voe
INPUT RESISTANCE CHECK.
5-6.
100
mV,
1000 mV, and 10 V
Ranges.
Input
resistance
on
the
three
lower
ranges is
>
1010
ohms,
and is
most
easily checked
on
the 1 O V
range using the
following procedure:
5-2
a.
Connect
de standard to 3484A
input as
shown
in
Figure
5-2,
using
a
10 MQ
±
1%
resistor
for
Rs·
The
capacitor in
parallel
with
Rs
reduces
the
effect
of
noise.
Connect
jumper
across
Rs·
Set
3484A
RANGE
to
10
V,
FUNCTION
to
VDC.
b. Set de
standard output
to+
10.000
V.
T
able
5-2.
DCV Accuracy
and
Linearity Check.
DC
STANDARD
3484A
DISPLAY
LIMITS
VOLTAGE
RANGE
±
100.000
mV
lOOmV
±
99.97
mV to
100.03
mV
±
90.000
mV
100 mV
±89.97
mV t
o
90.03
mV
±
80.000 mV
lOO
mV
±
79.97
mV to
80.03 mV
±
70.000
mV
lOOmV
±69.97
mV
to 70.03
mV
±
60.000 mV
100
mV
±
59.97
mV
to 60.03
mV
±
50.000 mV
100 mV
± 49.97
mV t
o 50.03
mV
±
40.000
mV
100mV
±
39.98
mV
t
o 40.02
mV
±
30.000
mV
100
mV
± 29.98
mV
to 30.02 mV
±
20.000
mV
lOOmV
±
19.98
mV to
20.02
mV
±
10.000 mV
lOOmV
±09.98 mV
t
o
10.02
mV
±
100.00 mV
l
OOOmV
±
099.9 mV
to 100.1 mV
±
300.00 mV
1000 mV
±
299.9 mV
to
300.1 mV
±
500.00 mV
1000 mV
± 499.8
mV to 500.2 mV
±
700.00 mV
1000
mV
±
699.8 mV
to
700.2 mV
±
900.00 mV
1000 mV
±899.8
mV
to 900.2
mV
±
1000.00
mV
1000
mV
±
999.8 mV
to
1000.2
mV
±
10.0000
v
10V
±
9.998
v
to 10.002
V
±
9.0000
v
10
v
±8.998
v
to 9.002
v
±
7.0000
v
10V
±6.998
v
to
7.002
v
±
5.0000
v
10
v
± 4.998
v
to 5.002
v
±
3.0000
v
10
v
±2.999
v
to
3.001
v
±
1.0000
v
10
v
±
0.999
v
to
1 .001
v
±
10.000
v
100
v
±
09.99
v
to
10.01
v
±
100.000
v
100
v
±99.98
v
t
o
100.0
2
V
±
1000.00 V
*
1000
v
±
999.8
v
to
1000.2 V
±
100.00
v
1000
v
±
099.9
v
to
100.1
v
*If
·hp-
Model 7408
is used
as
de standard, do
not
apply negative
voltage greater than
-
500
V
.
-
-
-
Table of
Contents
Previous
Page
Next
Page
1
...
35
36
37
38
39
40
41
42
Advertisement
Table of Contents
Troubleshooting
Techniques
46
Zero Offset Troubleshooting Tree
54
Related Manuals for HP 3484A
Control Unit HP 3497A Operating And Programming Instructions
Data acquisition/control unit (342 pages)
Control Unit HP HP 81531A User Manual
Sensor module (34 pages)
Control Unit HP 75000 B Series User Manual
Eight-channel fixed filter and amplifier signal conditioning plug-on (14 pages)
Control Unit HP 81531A User Manual
Sensor module (30 pages)
Control Unit HP E1407A Installation And User Manual
C-size active adapter module (32 pages)
Control Unit HP 81536A User Manual
Sensor module (30 pages)
Control Unit HP HP 1050 Series Installation And Maintenance Manual
Variable wavelength detector (90 pages)
Control Unit HP 81552SM Operating Manual
Lightwave multimeter source module (26 pages)
Control Unit HP 83487A User Manual
Optical/electrical plug-in module (98 pages)
Control Unit HP 70909A Installation Manual
Rf section (32 pages)
Control Unit HP SDGOB-1391 User Manual
802.11b/g/n wlan module (18 pages)
Control Unit HP E3456A User Manual
Emulation for the powerpc mpc500 (171 pages)
Control Unit HP 83400 Series Getting Started
Lightwave source and receiver modules (77 pages)
Control Unit HP Synergy 480 Gen9 User Manual
Compute module (66 pages)
Related Products for HP 3484A
HP 3497A
HP 3498A
HP 348773-001
HP 348 G3
HP HP 348 G7
HP 348 G5
HP 345646-001 - StorageWorks NAS 2000s External Storage Server
HP 345561-001
HP ProCurve 3400cl-24G
HP 3468B
HP 3458A
HP StorageWorks 344181-B21
HP 3455A
HP 3400A
HP 340 G5
HP 3490A
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL