1.2 General UL/ULC-Compliance
A UL-compliant installation requires the following:
• The PW7K1ICE panel must be installed within the protected area.
• The PW7K1ICE is installed for indoor use only.
• The PW7K1ICE must be installed with the provided tamper switch, mounted
• The fail secure locking mechanism shall only be installed where is allowed by
• Shielded cable shall be employed for all Input/Output wiring.
The PW7K1ICE panel is not UL Listed for burglary installations.
Note:
The following applies to installations that require UL or ULC compliance:
Note:
• Only UL/ULC Listed readers with standard Wiegand data output
• This product is intended to be installed indoors, within the protected premises.
• Access Control System, Model PRO4200, and Controller, Model PRO42IC
• This product's compliance to ULC-S319, Electronic Access Control Systems,
• All unused conduit holes must be properly plated or incorporate a Listed plug
Total current draw for all included assemblies shall not exceed 4A, including
Note:
input rating and output load current.
• Suitable for S319, Class I
• Suitable for the following UL293/UL294 Performance Levels:
• Endurance: IV
• Standby: I
• Line Security: I
• Attack: I
• Suitable panic or exit hardware shall be employed for fail secure applications.
PW7K1ICE Installation and Configuration Guide, Document 800-26497
to the enclosure cover.
the local authority having jurisdiction (AHJ), and it shall not impair the
operation of panic hardware and emergency egress.
communication format (protocol) have been evaluated for use with this
system.
meet the requirements for CAN/ULC-S319-05 Equipment Class 1.
will be considered invalidated through the use of any add-on, expansion,
memory or other module manufactured or supplied by the manufacturer or
manufacturer's representative, unless specifically evaluated by ULC.
to fill any voids.
For UL293 applications, the Sys Fault contacts of the power supply and the
door held, door forced shall be monitored by suitable audible device.
PW7K1ICE Introduction
General UL/ULC-Compliance
7