HEATER SIZING GUIDELINES
Radiant heaters work like the sun to emit radiant heat directly to the space to increase the comfort of
the patio guests. Suitable applications include patios, porches, outdoor shopping areas and pathways.
The amount of temperature increase in outdoor patio spaces will be dependent on the following factors:
1. The number of heaters in the space is important to provide good coverage of the area to be heated.
2. Take care not to mount the heaters too low or too close together this can make people directly below the
heaters uncomfortable.
3. It is recommended to use a suitable windbreak to reduce the effects of direct wind on the patio. If an area
is going to be unprotected and is a breezy location then heaters may need to located closer together. Wind
breaks must be designed to allow fresh air for ventilation.
4. Angling the heaters greater than 30 degrees should be avoided unless the mounting height is low, when
the heaters are angled more than 30 degrees the radiant intensity is lower and will reduce the amount of
heat felt by the guests.
5. It is recommended to place the heaters in the area of greatest heat loss facing into the patio area.
The table below shows minimum area coverage per heater for outdoor patio heating based on a 5 to
10°F (2.8 to 5.6°C) temperature rise.
Mounting Angle
Horizontal
Up to 30 Degrees Angled
30 to 60 Degrees Angled
Note: When sizing the number of heaters to warm the patio, the area coverage given above may not
provide the stated temperature rise under all weather conditions and will be dependent on heater
placement. Minimums are shown as a guideline for human comfort. For more assistance with patio
heater sizing and layout please contact your local Sunstar representative.
Mounting Height
Breezy Exposed
8ft. – 11ft.
(2.5 – 3.0m)
(2.5 x 2.5m)
7ft. – 9ft.
(2.1 – 2.7m)
(2.5 x 2.5m)
6ft. – 8ft.
(1.8 – 2.5m)
Moderately
Location
Protected
8 x 8 ft
10 x 10 ft.
(3.0 x 3.0m)
8 x 8 ft
9 x 9 ft.
(2.7 x 2.7m)
Not Recommended
Well
Protected
12 x 12 ft.
(3.7 x 3.7m)
11 x 11 ft.
(3.3 x 3.3m)
8 x 8 ft.
(2.5 x 2.5m)

Advertisement

loading
Need help?

Need help?

Do you have a question about the SGL Glass Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SunStar SGL Glass Series

  • Page 1 Minimums are shown as a guideline for human comfort. For more assistance with patio heater sizing and layout please contact your local Sunstar representative.
  • Page 2 TYPICAL HEATER LAYOUTS The diagram below shows the recommended spacing layout between heaters. Dimension Horizontal 15 to 30 degree angle Above 30 degree angle Min. Max. Min. Max. Min. Max. A. Mounting Height 8ft (2.5m) 11ft 7ft (2.1m) 9ft (2.7m) 6ft (1.8m) 8ft (2.5m) (3.4m)