8- FAILURE LOCATION GUIDE

EQUIPMENT WITH LOW EFFICIENCY
Check:
WATER PUMP PERFORMANCE AND ELECTRICAL CONNECTIONS
a) Remove the upper cover.
b) Remove the water hose from the evaporator.
c) Using a container with a cm scale on it, turn on the pump and
collect the water for one cycle, which should be between 800 cm
(minimum) and 1500 cm3 (maximum).
If the water collected is below the minimum, check that:
The evaporator hose is not obstructed, bent or kinked.
The switch commanding the water cycle is properly set.
(See Water Cycle Setting before)
3
3
YES
NO