UNI 10683/98 – Chimney tops, distances and
positioning, Roof slant; distance between the ridge
cap and chimney; minimum chimney height , less than
1,85 m; greater than 1,85 m; 0,50 m beyond the ridge
cap;1,00 m from the roof .
5.4
SMOKE OUTLET CONNECTION
Dimensioning the ue must be executed in accordance
with EN 13384-1.
• The SMOKE connection between the cooker and
ue should have the same cross section as the cooker's
smoke outlet. The smoke tting must be sealed and the
use of exible metallic pipes is prohibited.
• In order to connect the cooker to the chimney you may
perform maximum 3 changes of direction that should not
exceed 90°, the fume duct should not exceed 2 metres
in length and 3 metres in total (
• if the outlet is placed on the ceiling, make sure that the
rst vertical section has at least 50 cm before changing
the direction.
• Follow the indications in the technical data sheet
regarding the chimney draught value.
The appliance cannot be used in a shared ue.
INSTALLAZIONE
).
004773902 - 01/2018 - PALAZZETTI - PN - Italy
A
Fig. 5.2.1
2,00 m
Fig. 5.2.2
Fig. 5.2.3
> 5 m
0,50 m
Fig. 5.2.4
> A
Fig. 5.2.5
C
OMIGNOLI
0,40 m
NO
5 m
B
A
B
0,50 m
asse del colmo
UNI 10683/98
,
DISTANZE E POSIZIONAMENTO
9