Intertek F18B411 Manual page 13

Gas stand-up heater
Table of Contents

Advertisement

Lighting:
1. Turn on the valve on the gas cylinder.
2. Press and turn the control knob to PILOT position (anti-clockwise 90º). (Figure 1)
3. Holding down the control knob, press the igniter button several times until the main flame is ignited. Release the
control knob 10 seconds after the ignition.
4. Press lightly and turn the variable control knob to HI (maximum) position and leave it there for 5 minutes or more
before turning the knob to the desired temperature setting. (Figure 2)
5. If the burner flame goes out, turn off the heater and wait at least 5 minutes or more to let the gas dissipate before
re-lighting to avoid gas explosion.
Repeat steps 2 to 4.
Note:
Improper operation can cause injury or property damage. If pilot fails to remain lit, all valves
should be closed and you should wait for at least 5 minutes before attempting to light it again.
If you experience any ignition problem, please consult "Troubleshooting" on page 17.
Caution:
Avoid inhaling fumes emitted from the heater's first use. Smoke and odour from the burning of oils used in
manufacturing will appear. Both smoke and odour will dissipate after approximately 30 minutes. The heater should NOT
produce thick black smoke.
Note:
The burner may be noisy when initially turned on. Turn the knob to the level of heat desired.
Figure 1
in.
in.
in.
Normal
Figure 2
in.
in.
in.
Abnormal
13
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

F18g412F18s413