AGF COLLECTanDRAIN 5400 Owner's Manual

Auxiliary drain
Hide thumbs Also See for COLLECTanDRAIN 5400:

Advertisement

Quick Links

AGF Manufacturing Inc.
Model 5400
Owner's Manual
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COLLECTanDRAIN 5400 and is the answer not in the manual?

Questions and answers

Summary of Contents for AGF COLLECTanDRAIN 5400

  • Page 1 AGF Manufacturing Inc. Model 5400 Owner’s Manual...
  • Page 2: Table Of Contents

    AGF Manufacturing Inc. TABLE OF CONTENTS Installation Instructions ............... 4-7 Unpacking ..................4 Sprinkler System Preparation ............4 Mounting ...................4 Wiring ....................5 Verify Correct Operation ............... 6-7 Operating Instructions ..............7-8 Maintenance Instructions ............9-11 Verify Alarm Operation ..............9-10 Heater Operation ................9 Changing Timer Setting ..............10...
  • Page 3 The M5400 maintains a comfortable temperature above freezing while minimizing power consumption. System Supply Pipe Electrical Connection System Supply Valve “TEST” Button Alarm Light System Drain Valve Heater System Drain Pipe Drain Pipe Cap AGF Manufacturing Inc. • Phone: 610-240-4900 • Fax: 610-240-4906 • www.testandrain.com...
  • Page 4: Installation Instructions

    Model 5400 COLLECT DRAIN Owner’s Manual ® INSTALLATION INSTRUCTIONS Unpacking: Unpack the COLLECT DRAIN M5400 unit and carefully inspect for any ® damages from shipping. Verify box contents: • COLLECT DRAIN M5400 unit ® • Four (4) Rubber Mounting Washers •...
  • Page 5: Wiring

    Connect one wire to the AC1 (auxiliary contact) Terminal. Connect the other wire to the AC2 (auxiliary contact) Terminal. Connect these wires to the appropriate place in the Remote Panel. AGF Manufacturing Inc. • Phone: 610-240-4900 • Fax: 610-240-4906 • www.testandrain.com...
  • Page 6: Verify Correct Operation

    The default setting of 50º F is adequate for outside temperatures down to 0º F. If operating below this temperature, the set- point should be increased. Consult AGF for set-point guidelines. Install the M5400A Alarm Panel Cover and tighten the four screws securely.
  • Page 7: Operating Instructions

    The factory default setting of 50º F is suitable for conditions down to 0º F. Consult with AGF for recommended settings if operating the M5400 in areas below 0º F. The thermostat controls the heater operation to within approximately ± 10º F of the set-point (i.e.
  • Page 8 Model 5400 COLLECT DRAIN Owner’s Manual ® auxiliary contact is also triggered and is capable of being wired back to a central control panel for remote indication. The Level Alarm is automatically reset when the water level is drained below the switch. The M5400 is equipped with a “TEST”...
  • Page 9: Maintenance Instructions

    120V power is present. Loosen the four screws on the front of the M5400H Alarm Panel Box and carefully remove the cover. Take note of the current thermostat set-point. Thermostat Set-Point: __________________ AGF Manufacturing Inc. • Phone: 610-240-4900 • Fax: 610-240-4906 • www.testandrain.com...
  • Page 10: Changing Timer Setting

    The default setting of 50º F is adequate for outside temperatures down to 0º F. If operating below this temperature, the set- point should be increased. Consult AGF for set-point guidelines. Disconnect electrical power to the M5400.
  • Page 11: Maintenance Log

    ________________________________________________ ________ _________ ________________________________________________ ________ _________ ________________________________________________ ________ _________ ________________________________________________ ________ _________ ________________________________________________ ________ _________ ________________________________________________ ________ _________ ________________________________________________ ________ _________ ________________________________________________ ________ _________ ________________________________________________ ________ _________ ________________________________________________ ________ AGF Manufacturing Inc. • Phone: 610-240-4900 • Fax: 610-240-4906 • www.testandrain.com...
  • Page 12: Agf Manufacturing Inc

    AGF Manufacturing Inc. 100 Quaker Lane • Malvern, PA 19355 Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com...