Kenwood TK-3200L Service Manual page 18

Uhf fm transceiver
Hide thumbs Also See for TK-3200L:
Table of Contents

Advertisement

Common Section
Item
Condition
1.Setting
1) BATT terminal voltage:7.5V
2) SSG standard modulation
[Wide] MOD:1kHz,DEV:3kHz
[Narrow] MOD:1kHz,DEV:1.5kHz
2.VCO lock
1) CH:High
voltage RX
2) CH:Low
3.VCO lock
3) CH:High
voltage
PTT:ON
TX
4) CH:Low
PTT:ON
Transmitter Section
Item
Condition
1.Frequency
1) CH:High
Adjust
2) PTT:ON
2.High power TEST CH: Low
Adjust
Low'
Center
High'
High
(5 points)
BATT terminal voltage:7.5V
PTT:ON
3.Low power TEST CH: Low
Adjust
Low'
Center
High'
High
(5 points)
BATT terminal voltage:7.5V
PTT:ON
4.DQT
TEST CH: Center
balance Adjust
Low
[Wide]
High
(3 points)
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
ADJUSTMENT
Measurement
Test equipment
Terminal
Power meter
ANT
DVM
CV
Measurement
Test equipment
Terminal
Frequency counter ANT
Power meter
Ammeter
Power meter
Deviation meter
Oscilloscope
AG
AF VTVM
TK-3200L
Adjustment
Parts
Method
TC2
2.5V
Check
TC1
3.0V
Check
Adjustment
Parts
Method
VR1
High frequency
±50Hz
Programming
2.0W
Software:KPG-88D
1.0W
Make the
demodulation
wave into
square waves.
Specifications/
Remark
±0.1V
0.6V or more
±0.1V
0.6V or more
Specifications/
Remark
Note: After replacing
the TCXO (X1) align
frequency.
±0.1W
1.3 A or less
±0.1W
1.0 A or less
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents