This documentation as well as the corresponding software are subject to copyright law and protected by RESI company. All rights reserved. Copyright 2009-2015 RESI Informatik & Automation GmbH 23.02.2014...
RESI® History Date Editor Description 08.03.14 DI HC Sigl First English version 23.02.15 DI HC Sigl Minor revisions Datum Seite Manual RESI-DMX-MODBUS converter Titel: 23.02.2015...
Operating our device close to equipment, which do not comply with EMC directives, can influence the functionality of our device, leading to malfunction or in worst case to a breakdown of our device! Datum Seite Manual RESI-DMX-MODBUS converter Titel: 23.02.2015...
Page 5
Dimensions of the enclosures or enclosures accessories may show slight tolerances on the specifications provided in these instructions! Modifications of this documentation is not allowed! In case of a complaint, only complete devices returned in original packing will be accepted! Datum Seite Manual RESI-DMX-MODBUS converter Titel: 23.02.2015...
RESI® General Information Our RESI-DMX-ASCII converter is designed for controlling a DMX light system with a DMX universe of 512 DMX addresses. The control is done with simple ASCII commands or with MODBUS/RTU registers. Our RESI-DMX-MODBUS converter is designed to control a DMX light system with the MODBUS/RTU protocol.
Page 7
LED indicator Clamps Clamp wire cross section Max. 1,5 mm² Tightening torque Max. 0.5Nm CE conformity IT Accessories RESI-MODBUS- Free configuration software for RESI Modbus devices. Download this software from Configurator www.RESI.cc Datum Seite Manual RESI-DMX-MODBUS converter Titel: 23.02.2015...
Mounting and Connections Assembling Our RESI-DMX-ASCII and RESI-DMX-MODBUS converters are designed for mounting on a 35mm DIN- EN50022 rail. Please note, that there are symbol photos used in the mounting pictures below. At first, put the converter with the top side on the DIN rail (1).
DMX lamps. HOST HOST LED, Flashes shortly, if the HOST communicates with the converter. Table: Description of connectors and LEDs of the RESI-DMX-MODBUS converter Datum Seite Manual RESI-DMX-MODBUS converter Titel:...
After changing the DIP switches the converter reboots immediately, so no power off or on is necessary. After reboot all the LEDs are on for half a second to signal the power on sequence. Table: Description of DIP Switch functions Datum Seite Manual RESI-DMX-MODBUS converter Titel: 23.02.2015...
ASCII messages. The converter also offers the possibility to control the 512 DMX lights via a MODBUS/RTU based serial interface of an automation device, because the converter is also a MODBUS/RTU slave. The RESI-DMX-MODBUS converter is designed to control a DMX light system with MODBUS/RTU protocol.
RESI® MODBUS - Registers Hint Both converters, the RESI-DMX-ASCII and the RESI-DMX-MODBUS offer a MODBUS/RTU slave protocol for communication. Overview Register Range Function 4x00001 DMX Universe with 512 DMX register 4x00512 4x00513 unused 4x05999 4x06000 Converter internally 4x06009 4x06010 Unused...
DMXLENGTH is a value between 1 and 512 and defines the amount of DMX registers, which are sent cyclically to the DMX bus. After a reset or power on, this register has always the value 512 and the converter sends ALL 512 DMX registers. Datum Seite Manual RESI-DMX-MODBUS converter Titel: 23.02.2015...
Description DMXFILL DMX 8 Bit value used for filling ALLE DMX Register Write: Fills ALL 512 DMX registers with the new 8 Bit value. Read: Returns the last used 8 bit fill value. Datum Seite Manual RESI-DMX-MODBUS converter Titel: 23.02.2015...
If the set value is greater than 3, the standard baud rate of 19200 bps is used! To overwrite the old values it is necessary to save the new configuration and to restart the converter. Datum Seite Manual RESI-DMX-MODBUS converter Titel: 23.02.2015...
Enclosure dimensions L x W x H (mm) 17,5 x 90 x 58 Weight 60 g Colour Grey RAL7035 Material PA - UL 94 V0 Protection class IP20 based on DIN 40050/EN 60529 Table: Data of enclosure Datum Seite Manual RESI-DMX-MODBUS converter Titel: 23.02.2015...