2.5.2 A 2-Channel Meter

For the 2-Channel Model GS868, the information entered in the
channel.
1. At the User Program screen shown, press the
2. Enter a Channel Label of up to 9 characters. Press
3. Enter a Channel Message of up to 21 characters. Press
Note: For the 2-Channel Model GS868, the
not required to make the unit operational, are located in the
details.
SYSTM
The remainder of the
Proceed to the 1- and 2-Channel Meters section below to complete the programming of this submenu.

2.5.3 1 and 2-Channel Meters

1. At the Equation prompt, press
display the measurement data in actual volumetric units. The GS868 uses the appropriate gas equation to calculate
the flow rate in the volumetric units indicated.
and  ] keys to select the desired Volumetric Units for the flow rate display.
[F1]-[F4]
2. Use the
The abbreviations and definitions of all the available volumetric and totalizer units are shown in Table 4 below. The
choices shown on the option bar are determined by the selection made at the previous
[F1]-[F4]
3. Use the
keys to select the Volumetric Time (units for the volumetric flow rate display).
[F1]-[F4]
4. Use the
keys to select the Vol Decimal Digits (the desired number of digits to the right of the decimal
point) in the volumetric flow rate display.
[F1]-[F4] and
5. Use the
The abbreviations and definitions of all the available volumetric and totalizer units are shown in Table 4 on page 27.
The choices shown on the option bar in the prompt screen above are determined by the selection made at the previous
SYSTEM UNITS
prompt screen.
DigitalFlow™ GS868 Startup Guide
System Units, Pressure Units
submenu is identical for the 1-Channel and 2-Channel versions of the Model GS868.
[F1]
to display the measurement data in standard volumetric units, or press
Table 4: Available Volumetric/Totalizer Units
English
ACF = Actual Cubic Feet
KACF = Thousands of ACF
MMACF = Millions of ACF
SCF = Standard Cubic Feet
KSCF = Thousands of SCF
MMSCF = Millions of SCF
[ keys to select the Totalizer Units.
SYSTM
submenu pertains only to the currently selected
[F2]
function key to program the
[ENT]
.
[ENT]
.
GLOBL
Metric
Actual Units
ACM = Actual Cubic Meters
KACM = Thousands of ACM
MMACM = Millions of ACM
Standard Units
SCM = Standard Cubic Meters
KSCM = Thousands of SCM
MMSCM = Millions of SCM
SYSTM
submenu.
Stopwatch Totalizer
and
submenu. See the Programming Manual for
SYSTEM UNITS
Chapter 2. Initial Setup
prompts, which are
[F2]
to
screen.