GE DigitalFlow GS868 Startup Manual page 18

Panametrics steam ultrasonic mass flowmeter
Hide thumbs Also See for DigitalFlow GS868:
Table of Contents

Advertisement

Chapter 1. Installation
1.6.1 Wiring the Line Power (cont.)
1. Remove the plastic shroud that covers the terminal blocks. Be sure to reinstall the shroud after all of the wiring has
been completed.
2. Strip ¼" of insulation from the end of the power and neutral or line leads (or the positive and negative DC power
leads), and ½" from the end of the ground lead.
3. Connect the ground lead to the internal ground connection located on the side panel of the inclosure (see Figure 3
below).
IMPORTANT:
The incoming ground lead must be connected to the internal ground connection.
4. Connect the neutral or line lead (or the negative – DC power lead) to
+ DC power lead) to TB1-3 as shown in Figure 3 below.
IMPORTANT:
Do not remove the existing PC board ground wire or the cover ground wire.
8
G –
G
N/L2
PC Board
Ground Wire
Cover
1
2
Ground Wire
Internal
Ground
Connection
Figure 3: Wiring the Line Power
TB1-2
and the line power lead (or the positive
+
DC
L1
AC
TB1
3
AC Line Power
or DC +
AC Neutral/Line
or DC –
DigitalFlow™ GS868 Startup Guide

Advertisement

Table of Contents
loading