6.1

T17 Transducer Physical Specifications

Applications:
Installation Type:
Materials of Construction:
Field Mounting:
Process Connection:
Holder Type:
Holder Ratings:
Electrical Rating:
Operating Temperature:
Storage Temperature:
Operating Pressure:
Operating Frequency:
6.2

T17 Transducer Certifications

North American -
Explosion proof:
European/International -
Flameproof:
North American -
Weatherproof:
European/International -
Weatherproof:
Model T17 Installation Guide
Hazardous Area applications, Flare Gas, Hydrocarbon Gases using
GE ultrasonic flow meter Models GF868 and XGF868i
Wetted
Standard: Titanium
Optional: 316 Stainless Steel, Monel
Flowcell, Hot or Cold Tap
Flanged, 3 in. (80 mm)
Insertion Mechanism
150#, 300#
200 V peak-to-peak, 5 mA
–67° to +300°F (–55° to +150°C)
–67° to +300°F (–55° to +150°C)
12.7 to 1500 psia (87.6 to 10300 kPa)
100 kHz
Class I, Division 1, Group C, D
Class II, Class III, Division 1, Group E, F, G
Single Seal
II 2 G Ex d IIC T6...T2 Gb (T code dependent on Process Temperature)
o
Tamb –40° to +140
F (–40° to +60
KEMA 01ATEX2045X: IECEx KEM09.0009X
Standards used: EN 60079-0:2012, EN 60079-1:2007, IEC 60079-0:2011,
IEC 60079-1:2007, Ed. 6.
IP66, TYPE 4X
200Vpp, 5mA
IP 66
or Hastelloy
o
C)