Chapter 5. T9 Specifications
5.1 Specifications
Transducer
Designation
Installation Type
Material
Field Mounting
Process Connection
Holder Type
Holder Ratings
Operating Frequency
Pressure Range
Electrical Rating
Ambient Temperature Range
Process Temperature Range
Model T9 Ultrasonic Flow Transducer Installation Guide
Table 2: T9 Transducer Specifications
Hazardous area applications; flare gas, hydrocarbon gases, saturated steam.
Wetted
Standard: Titanium
Optional: 316SS, Monel
Flowcell, hot or cold tap
1.5 in. (40 mm) flanged
Simple, barrel or flanged holder
150#, 300#, 600#
100 kHz
0 to 2700 psig
200 V peak-to-peak, 5 mA
Europe: -40 to +158°F (-40 to +70°C)
North America: -4 to +140°F (-20 to +60°C)
Normal Temperature: -58 to +302°F (-50 to +150°C)
High Temperature: -58 to +500°F (-50 to +260°C)
T9 Specification
or Hastelloy
Chapter 5. T9 Specifications
31