Warranty Conditions - Hornbach AQUA 1100 Manual

Table of Contents

Advertisement

Available languages

Available languages

Symptom
Fluctuating pressure
Machine stops
Fuse blows
Machine pulsating
Machine often starts
and stops by itself
Machine starts, but no
water comes out
In case problems other than the above occur, please contact your local Nilfi sk distributor. Local Nilfi sk
distributors are listed on the back cover of this instruction.

8 Warranty Conditions

Nilfi sk guarantees high pressure washers for domestic use for 2 years. If your high pressure washer
or ac ces so ries are handed in for repair, a copy of the receipt must be enclosed.
Guarantee repairs are being made on the following con dit ions:
• that defects are attributable to fl aws or defects in materials or workmanship. (wear and
tear as well as misuse are not covered by the gu a ran tee).
• that the directions of this instruction manual have been thoroughly observed.
• that repair has not been carried out or attempted by other than Nilfi sk-trained service
staff.
• that only original accessories have been applied.
• that the product has not been exposed to abuse such as knocks, bumps or frost.
• that only water without any impurities has been used.
• that the high pressure washer has not been used for rental nor used com mer cial ly in
any other way.
Repairs under this guarantee include replacement of defective parts, exclusive of packing and posta-
ge/carriage. Besides, we refer to your national law of sale.
Original Instructions
Cause
Pump sucking
Valves dirty, worn out or stuck
Pump seals worn out
Fuse has blown
Incorrect mains voltage
Thermal sensor activated
Nozzle partially blocked
Fuse too small
Air in inlet hose/pump
Inadequate supply of mains
water
Nozzle partially blocke
Water fi lter blocked
Hose kinked
Pump/spray handle is leaking
Pump/hoses or accessory
frozen
No water supply
Water fi lter blocked
Nozzle blocked
Recommended action
Check that hoses and connections are air-
tight.
Clean and replace or refer to local Nilfi sk-
distributor.
Clean and replace or refer to local Nilfi sk-
distributor.
Replace fuse. Switch off other machines.
Check that the mains voltage corresponds
to specifi cation on the model tag.
Leave the washer for 5 minutes to cool
down.
Clean the nozzle.
Change to an installation higher than the
amp. consumption of the machine.
You may try without the extension cable.
Allow machine to run with open trigger until
regular working pressure resumes.
Check that the water supply corresponds to
specifi cations required (see model tag)
NB! Avoid using long, thin hoses (min. 1/2")
Clean the nozzle.
Clean the fi lter.
Straighten out hose.
Contact your nearest Nilfi sk Service Centre.
Wait for pump/hoses or accessory to thaw.
Connect inlet water.
Clean the fi lter.
Clean the nozzle.