REMOTE CONTROL UNLOCK / REENABLING ........................21 5.1.5 ON OFF UNIT / MODE AND SPEED SELECTION ........................21 5.1.6 SYSTEM STATUS REQUEST ..............................22 5.1.7 AUTOMATIC OPERATION ..............................22 5.1.8 EXTRA CYCLE OPERATION AND MODULATING REGENERATIVE RECOVERY ..............23 Innova Srl Page 2 N420220A_ManualeHRC_Rev07.EN...
The unit must be powered with electrical cables with a section suitable for the power of the unit. The voltage and frequency values must correspond to those indicated for the respective machines; all the machines must be earthed as per the regulations in force in the various countries. Innova Srl Page 4 N420220A_ManualeHRC_Rev07.EN...
After connecting the electrical cables, make sure that the cables are arranged so as not to exert excessive forces on the covers or electrical panels; any incomplete connection of the covers can cause overheating of the terminals. Innova Srl Page 5...
The plate on the packaging has no validity for the traceability of the product in the years following the sale. The removal, deterioration and illegibility of the plate placed on the unit leads to major problems in identifying the machine, in the availability of spare parts and therefore in any future maintenance. Innova Srl Page 6 N420220A_ManualeHRC_Rev07.EN...
0 ° C, up to a maximum of 40 ° C. 1.1.9 DISASSEMBLY AND DISPOSAL Do not disassemble or dispose of the product yourself. The disassembly, demolition, disposal of the product must be carried out by authorized personnel in compliance with local regulations. Innova Srl Page 8 N420220A_ManualeHRC_Rev07.EN...
(from below). Do not mount the unit with the sides in direct contact with the walls to avoid possible contact noises, insert rubber or neoprene strips in this case. Fig.1A Recommended positioning Innova Srl Page 9 N420220A_ManualeHRC_Rev07.EN...
Page 10
1.2m from the corner shared by the two walls when coring. Fig.1B Positioning two units Extract the exchanger from the telescopic tube using the special handle. (figure 2). Fig. 2 Exchanger extraction Innova Srl Page 10 N420220A_ManualeHRC_Rev07.EN...
Page 11
Release and check the attachment of the grille. -Insert the exchanger from the inside towards the end of the tube with a smaller diameter. Fig. 4 Positioning the external grill Fig.5 Exchange insertion Innova Srl Page 11 N420220A_ManualeHRC_Rev07.EN...
Page 12
(3) both on the motor door and on the cover (fig. 7). Fig. 7 Cable insertion Fix the motor holder in correspondence with the drain hole using screws and plugs (fig. 8). Fig.8 Motor holder fixing Innova Srl Page 12 N420220A_ManualeHRC_Rev07.EN...
-Red wire (+) -Black wire (-) The control unit can be positioned on box 503 or on the wall and has a fixing screw underneath for access to the Power supply and power supply connection internal parts. Innova Srl Page 13 N420220A_ManualeHRC_Rev07.EN...
3 - 4 - 5 - 6 Motors connection with direct logic in automatic operation Maximum two engines 7 - 8 - 9 - 10 Motor connection with inverse logic in automatic operation Live contact (220v) Innova Srl Page 14 N420220A_ManualeHRC_Rev07.EN...
3.1.4 POWER CONNECTION - VERSION E- The HRC version E unit has a direct 230/1/50 power supply; on the upper part of the unit we find an electronic board with two terminals for connection L and Power connection 3.1.5 WIRELESS REMOTE CONTROL The control unit has a wireless connection to the HRC unit.
The Master unit is already configured in the factory with its own remote control; Do not swap the remote controls of two master units, but use its own remote control for each unit; Master unit configuration Innova Srl Page 16 N420220A_ManualeHRC_Rev07.EN...
After a few seconds the remote control will show a sequence of LEDs as indicated in the central figure. The LEDs indicate the activated decoupling mode. Long press the SLEEP button to unpair all devices from the system. Master decoupling procedure Innova Srl Page 17 N420220A_ManualeHRC_Rev07.EN...
On and fan speed selection key The right switching key has three operating modes: -Auto: the unit alternates the flow between extraction and intake of air; -In: air intake only; -Out: air extraction only. Operation mode selection key Innova Srl Page 18 N420220A_ManualeHRC_Rev07.EN...
Above some buttons, there are signaling LEDs which, by requesting information to the fan unit, will indicate the operating status. Remote control version E Innova Srl Page 19 N420220A_ManualeHRC_Rev07.EN...
Page 20
Here are the icons of the keys and their meaning on the remote control: Speed Min. Med speed Max speed Auto speed operation with sensors of: Night Speed Operation -Temperature -Humidity -Light Display of main screen keys Innova Srl Page 20 N420220A_ManualeHRC_Rev07.EN...
As for the extraction only or input only function, the unit returns by itself to cycle mode after 30 minutes. -To turn off the system, press the ON-OFF button. Drive activation System shutdown Innova Srl Page 21 N420220A_ManualeHRC_Rev07.EN...
By pressing the Auto key, the unit enters the automatic mode. In this mode, the fan unit detects the environmental parameters (temperature, humidity and brightness) and carries out the procedures and processing indicated below to ensure the best environmental comfort. Automatic mode operation Innova Srl Page 22 N420220A_ManualeHRC_Rev07.EN...
Note: This feature is normally disabled; to Brightness sensor function enable it, see the paragraph “Parameter setting”. Innova Srl Page 23 N420220A_ManualeHRC_Rev07.EN...
- activation or deactivation of the light function Access to parameter configuration procedure The remote control will show steady LEDs to indicate: -Through the three fan speeds the desired humidity setting threshold between: Low - Medium and High Humidity threshold selection Innova Srl Page 24 N420220A_ManualeHRC_Rev07.EN...
Page 25
Night Led Off = Function disabled Press and hold the AUTO key until the central LED flashes quickly to exit the parameter configuration if there are no selections. Light sensor activation and parameter configuration output Innova Srl Page 25 N420220A_ManualeHRC_Rev07.EN...
- proceed with cleaning very gently using a vacuum cleaner or a compressor; -insert the exchanger back into its seat; -Reinstall the motor holder through the screws used and View for exchanger extraction fix the unit cover 6.1.3 GENERAL CLEANING OF THE UNIT Innova Srl Page 26 N420220A_ManualeHRC_Rev07.EN...
The radio control will indicate the need to replace the batteries by means of the flashes indicated on the side; Replace both remote control batteries with two new ones. It is mandatory to dispose of the batteries in special containers; Remote control batteries replacement Innova Srl Page 27 N420220A_ManualeHRC_Rev07.EN...
-Faulty power supply The fan does not change -Faulty control unit - Check or replace the control unit speed The fan does not change its -Faulty control unit - Check or replace the control unit operating mode Innova Srl Page 28 N420220A_ManualeHRC_Rev07.EN...
Page 29
The fan works with -Faulty control unit - Check or replace the control unit unexpected times The remote control does - Low batteries or faulty remote control -Check or replace the batteries not work Innova Srl Page 29 N420220A_ManualeHRC_Rev07.EN...
DFM - Exchanger and pipe inspection with DFM Refit the motor holder plate, arrange the wires and terminals; refit the cover with filter. Innova Srl Page 30 N420220A_ManualeHRC_Rev07.EN...
-Unscrew the four rear screws that support the standard plastic finish cover. -Place the chosen aesthetic cover and tighten the four screws supplied with the new cover. CVR - Aesthetic covers Innova Srl Page 31 N420220A_ManualeHRC_Rev07.EN...
The insulation consists of a double shell of coated insulation material. With the insulation kit, the diameter of the hole for installing the product becomes: HRC05S - 200mm HRC02S - 160mm KUA - Insulation kit Innova Srl Page 32 N420220A_ManualeHRC_Rev07.EN...
During installation it is advisable to fill in the summary table of the system in order to keep track of the settings made, in order to facilitate any maintenance interventions. ARAMETER ETTINGS OCAL NVIRONMENT Direction of rotation in the Alternate Cycle Innova Srl Page 33 N420220A_ManualeHRC_Rev07.EN...
Page 36
01- 20 21 re v.0 7 The data contained in this manual can be changed by the manufacturer without prior notice. Innova Srl Page 36 N420220A_ManualeHRC_Rev07.EN...