AXIOMET AX-101B Operation Manual

AXIOMET AX-101B Operation Manual

Advertisement

Quick Links

DIGITAL MULTIMETER
AX-101B
OPERATION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AX-101B and is the answer not in the manual?

Questions and answers

Summary of Contents for AXIOMET AX-101B

  • Page 1 DIGITAL MULTIMETER AX-101B OPERATION MANUAL...
  • Page 2 Ⅰ.GENERAL The instrument is a featured , stable and security small hand-held 31/2 digital multimeter. The instrument has the function of measuring DCV, ACV, DCA, resistance, temperature, diode positive drop and continuity test, thus it is a portable and desirable tool for users. The operation manual includes the relevant safety information and warning notice , Please read it carefully and strictly follow all the precautions .
  • Page 3 IV. ELECTRONIC SYMBOLS WARNING! HIGH VOLTAGE ! DC & AC DUAL INSULATION CONFORMITE EUROPEENNE LOW BATTERY FUSE V.GENERAL SPECIFICATION The maximum voltage is 500V rms between the voltage input terminal and ground . 10A terminal : without fuse . MA terminal fuse : φ5×20mm 200mA/250V Range selector : manual Backlight function : manual put on &...
  • Page 4 off the backlight . VII.MEASUREMENT OPERATION INSTRUCTION Please check 9V battery first ,set the knob to a proper position ,When battery is running low ,the LCD displays symbol .Please pay attention to the symbol beside the test leads jack .It’s a warning that the voltage and current under test should not exceed prescribed value .
  • Page 5 equipment ,and even bring the risk of electronic shock. Be sure to cut off power and check input terminal and the position of range knob.After confirmation, that there isn’t any error, turn on power .If the current range under test is unknown beforehand , set the knob to the highest range ,select a proper range according to the displaying value.
  • Page 6 NOTE: To avoid the damage of the instrument,when online measure the diode, be sure that power is turned off and capacitors are released completely. Diode knob can be used to measure voltage drop of diode or even other semiconductor devices. The forward voltage drop reading should be 0.5V ~0.8V to a semiconductor devices with normal structure, it’s open circuit when reverse voltage drop displays “1”, The corresponding pole of black test leads is “+”...
  • Page 7 1.DCV RANGE ACCURACY RESOLUTION 200mV ±(0.5%+2) 100uV 10mV 200V 100mV 500V ±(0.8%+2) Input impedance :all ranges :10MΩ;Overload protection:200mV range :250V DC or AC peak value,other range: 500V DC or AC peak value . 2.ACV RANGE ACCURACY RESOLUTION 200V ±(1.2%+10) 100mV 500V Input impedance :Approx 5MΩ;...
  • Page 8 5.SINE WAVE OUTPUT RANGE INSTRUCTION output value of sine wave signal is approx 50Hz.as a simple signal source ,output value of resistance is 47kΩ. This instrument has no overload protection , the calibrated equipment input level should be less than 10V ,to avoid the damage of the instrument.