Chapter 1 Meter Safety Standards This style of digital multimeter is designed and manufactured according to the safety requirements set out by the IEC61010-1 standards for electronic test instruments and the hand-hold digital multimeters. Its design and manufacture is strictly based on the provisions in the 1000V CATIII of IEC6060-1 and the Stipulation of 2-Pollution Grade.
Chapter 2 Characteristics • 500 counts measurement • ACV and DCV measurements reach up to 1000V • DC measurement accuracy reaches up to 0,1% • 0,1 Ω resistance resolution and 10µ V voltage resolution • Linear frequency measurement logic frequency/duty ratio measurement •...
Page 4
(5) Rotary switch Used for selecting measurement functions such AC voltage, DC voltage, millivolt, frequency/temperature, diode/continue、resistance and capacitance, microampere current, milliampere current, insulation resistance. (6) POWER switch Used for putting on or off the operating power for the meter. (7) SELECT key •...
Page 5
(15) LCD screen Used for displaying the measuring results and various symbols. Understanding Display Screen : Figure 2-2 LCD screen is shown as in Figure 2-2, with its every symbol’s meaning shown as in the Table 1: Number of Order Symbol Functions Indicating the measurement unit being ℃...
AVG MAX MIN Indicating the display value being the current value(MAX MIN),the maximum value(MAX),the minimum value(MIN) and MAX MIN the average value(AVG) Indicating it is now in the data-holding state Warning symbol that the input signal is the high-voltage Indicating it is now in the AC measurement state Indicating it is now in the DC measurement state Indicating the measurement value being negative Indicating the overload in the insulation resistance...
AC voltage and AC current are true effective values, which distinguishing this meter from the meters which only can measure the AC average value. ● Automatic and manual ranges: When turning on the meter’s power switch the meter defaults the automatic range state (AUTO displaying), and simultaneously it will automatically select the proper range according to the measured electric parameters.
Page 8
● When rotary switch being in the positions of mV, logic frequency, diode, resistance and capacitance, the maximum overload protection voltage will be 250V(effective value),while in the positions of µA/mA the protection current being 0.64A,and in the position of A. ●...
Page 9
±(0.1% +2) 10mV ±(0.1% +2) 500V 0.1V ±(0.1% +2) 1000V ±(0.1% +2) Notes: above accuracies can be guaranteed within the full range • AC Current Accuracy Range Resolution Voltage Drop 40Hz~400Hz 500µA 0.1µA ±(0.8% +4) 102µV/µA 5000µA 1µA ±(0.8% +4) 50mA 10µA ±(0.8% +4)
Page 10
5KΩ 1Ω ±(0.3% +5) 50KΩ 10Ω ±(0.3% +5) 500KΩ 100Ω ±(0.3% +5) 5MΩ 1KΩ ±(0.3% +5) 50MΩ 10KΩ ±(0.8% +5) Notes: above accuracies can be guaranteed within the full range • Capacitance Range Resolution Accuracy 50nF 0.01nF ±(2.5% +10) 500nF 0.1nF ±(2.5% +10) 5µF...
Page 11
● Linear Frequency Voltage/Current Frequency Range Sensitivity Resolution Accuracy Range 500mV 200mV 0.5V 5HzⅢ200KHz 500V 0.001Hz ±4counts (sine wave) 1000V 400V 5000µA 500mA 100mA Notes: Low voltage or low frequency would lower the accuracy. • Duty Ratio Frequency Range Duty Ratio Range Resolution Accuracy 0.01%...
Page 12
100M~250M 1MΩ 500V 500K~100M 0.1MΩ ±(1.5% +5) 100M~500M 1MΩ 1000V 1M~100M 0.1MΩ ±(1.5% +5) 100M~2G 1 MΩ Chapter 5 Maintenance Replacement of Batteries If symbol appears on the LCD screen during measurement, it indicates the total voltage of batteries being lower than 6.8V. For ensuring measurement accuracy, it is necessary to replace the batteries.