Main chapter overview Safety instructions Safety instructions ........................A.1.1 Wallbox Energy Control safety instructions ................A.1.1 Note to the owner and operator of the charging system ..........A.1.1 Intended use ........................A.1.1 Notes for people with a pacemaker (PM) or implantable cardioverter defibrillator (ICD) A.1.3...
Safety instructions Wallbox Energy Control safety instructions Safety instructions Note to the owner and operator of the charging system ● Read the operating manual before starting up the charging system. ● Ensure that all persons working on or using this charging system ○...
Page 6
Safety instructions - isolate. - secure against reactivation. - check absence of voltage. - ground and short-circuit. - cover or block off live parts in the vicinity. Reactivation is carried out in reverse order. ● Knowledge of the general and special safety reg‐ ulations and accident prevention regulations.
(ICD) wish to conduct activi‐ ties on charging systems and their devices in the in‐ tended manner, Heidelberg is not in a position to make any statement regarding the suitability of such medial devices. Heidelberg is not able to assess the pace‐...
Safety instructions pressure cleaner because the plug-in connection is not sealed against pressurized water. In case of malfunctions or failure of the charging sys‐ ● Disconnect the charging system from the power supply by switching off the respective circuit breaker in the building. Leave a sign with the name of the person authorized to switch on the circuit breaker.
Page 9
The value must not exceed 1 MΩ. Note The Wallbox has a surge protector. This may be considered in the course of mak‐ ing measurements. 2. Measurement of the secondary side of the charging system.
Safety instructions ● Test of the power-off condition in case of a short- circuit (Z For these measurements, connect the charging cou‐ pler to a test adapter for vehicle simulation in accor‐ dance with EN 61581-1. The measurements must be carried out with the adapter in the C mode.
Safety instructions Designation Technical specifications Protection rating IP54 Residual current detection DC 6 mA Ambient temperature -25 °C to +40 °C Ventilation No ventilation required Protection class Overvoltage category Dimensions (HxWxDx) 386 mm x 295 mm x 112 mm Weight approx.
Optional external blocking device If an external blocking device (e.g. key switch) is con‐ nected, the charging process is only started when the Wallbox has been enabled by the external blocking device. Declaration of Conformity The Declaration of Conformity and the CE marking on...
Page 13
Safety instructions Wallbox Energy Control Fig. 3 Declaration of Conformity A.1.9 00.999.3046/...
Need help?
Do you have a question about the Wallbox and is the answer not in the manual?
Questions and answers