LG VX10000 Service Manual page 97

Dual band cdma [pcs/cellular/gps/media flo] cdma mobile phone
Hide thumbs Also See for VX10000:
Table of Contents

Advertisement

VX10000
Check the clock to Camera
at L3003 (48MHz)
Check the clock from Camera
at R6006 : CAM_PCLK
Check the voltage of
the following LDOs :
+2.8V_CAM_AVDD
+2.8V_CAM_VDD
Check the Control signal
CAM_DATA[0:7], CAM_RESET/,
CAM_SDA, CAM_SCL
Check CON6003 Soldering
Camera will work properly
Copyright © 2007 LG Electronics. Inc. All right reserved
Only for training and service purposes
Checking Flow
START
YES
YES
+1.8V_CAM_VDD
YES
YES
YES
Checking Flow
Replace U3006
NO
Replace the Camera module
NO
Replace the U5004, U5005
NO
Check the F6002, F6003,F6004,F6005(Signal line)
NO
NO
- 96 -
Re-solder CON6003
LGE Internal Use Only

Advertisement

Table of Contents
loading