LG VX10000 Service Manual page 110

Dual band cdma [pcs/cellular/gps/media flo] cdma mobile phone
Hide thumbs Also See for VX10000:
Table of Contents

Advertisement

VX10000
SETTING : After initialize 5515C, Test Cellular
START
Check the voltage level
at R2014 is 1.0~2.0V
Check the signal level
at each side of MIC.
Check the soldering
at C2004, C2008
Check the soldering of
MIC NETWORK
MIC will work properly
Copyright © 2007 LG Electronics. Inc. All right reserved
Only for training and service purposes
Checking Flow
Checking Flow
No
Yes
No
Yes
No
Yes
No
Yes
Check the soldering
Of R2014
Yes
Replace MSM
Replace the microphone
Re-soldering
C2004, C2008
Re-solder MIC NETWORK
- 109 -
No
Re-solder R2014
LGE Internal Use Only