START
Charging Connector CON6004
Well-soldered?
Voltage at U5001, U5009
Pin 6 = 5V ?
0.1V < Voltage of CHAR_MON< 1.22V
Voltage of pin 1 CON5001 =
VBATT(+VPWR)
Is the battery charged?
Charging will operate properly
Copyright © 2007 LG Electronics. Inc. All right reserved
Only for training and service purposes
Checking Flow
Checking Flow
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
Re-soldering CON6004
The charging adaptor (TA) or USB cable(USB port
of computer) is out of order.
Replace Q5005
Check the soldering
YES
Replace Q5002
The battery may have the problem.
Change the battery and try again.
- 91 -
NO
Re-solder Q5002