Code Parameter
D.083 DHW burner starts
D.084 Maintenance in
D.088 Min. DHW flow rate
D.090 eBUS controller
D.091 Status DCF77
D.092 actoSTOR communication status
D.093 Adjust Device Specific Number
D.094 Clear fault history
D.095 Software version: PeBUS parti-
cipant
D.096 Reset to factory settings?
D.098 Coding resistor
0020244998_04 ecoTEC plus Installation and maintenance instructions
Values or explanations
Number of burner start-ups
Adjustment range: 0 to 3000 hrs and "---" for deactivated
Switch-on delay for domestic hot water draw-off detec-
tion via impeller (only products with integrated domestic
hot water generation)
0 = 1.5 l/min and no delay,
1 = 3.7 l/min and 2 sec. delay
Status of digital control
Recognised, not recognised
Status of DCF with outdoor temperature sensor connec-
ted
No reception
Reception
Synchronised
Valid
actoSTOR module detection
0 = Not connected
1 = Connection fault: No communication via PeBus,
actoSTOR module was previously detected
2 = Connection active
Device Specific Number (DSN)
Adjustment range: 0 to 99
Delete fault list
0 = No
1 = Yes
PCB (BMU)
Display (AI)
actoSTOR (APC)
HBI/VR34
Reset all adjustable parameters to factory setting
0 = No
1 = Yes
Display xx.yy
xx = Coding resistor 1 in cable harness for output range:
8 = VU 126/5-5 (H-GB) ecoTEC plus 612; VU 156/5-5
(H-GB) ecoTEC plus 615; VU 186/5-5 (H-GB) ecoTEC
plus 618, VU 186/5-5 (P-GB) ecoTEC plus 618; VUW
196/5-5 (H-GB) ecoTEC plus 825
9 = VU 246/5-5 (H-GB) ecoTEC plus 624; VUW 246/5-5
(H-GB) ecoTEC plus 832; VUW 246/5-5 (P-GB) ecoTEC
plus 832
10 = VU 306/5-5 (H-GB) ecoTEC plus 630; VU 306/5-5
(P-GB) ecoTEC plus 630; VUW 306/5-5 (H-GB) ecoTEC
plus 835
11 = VU 386/5-5 (H-GB) ecoTEC plus 637; VUW 286/5-
5 (H-GB) ecoTEC plus 838; VUI 286/5-5 (H-GB) ecoTEC
plus 938
yy = Coding resistor 2 on PCB for gas group:
02 = P gas
03 = H gas
07 = L gas
Factory
Own setting
setting
Not ad-
justable
„---"
1.5 l/min and
no delay
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
55