WAGNER Layer Check LC 1000 Translation Of The Original Operating And Manual

WAGNER Layer Check LC 1000 Translation Of The Original Operating And Manual

Layer check non-contact layer thickness measurement
Table of Contents

Advertisement

Quick Links

Version 03/2018
Layer Check
LC 1000
Non-contact layer thickness
measurement
P_03487

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Layer Check LC 1000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for WAGNER Layer Check LC 1000

  • Page 1 Version 03/2018 Layer Check LC 1000 Non-contact layer thickness measurement P_03487...
  • Page 3: Table Of Contents

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL Table of Contents ABOUT THESE INSTRUCTIONS Preface Warnings, Notices and Symbols in these Instructions Languages Abbreviations Terminology for the Purpose of this Manual CORRECT USE Device Type Type of Use Field of Application Misuse Warranty Conditions...
  • Page 4 Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL ASSEMBLY AND COMMISSIONING Training of Assembly/Commissioning Personnel Storage Conditions Transport Inspection Assembly and Installation 6.4.1 Installation and Connecting to the Mains 6.4.2 Assembly of Additional Components (Example) Software Environments Connecting with the PC Network and Administrator Settings 6.7.1 Configuring the Layer Check Network Access...
  • Page 5 Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL REMOTE CONTROL TCP/IP 8.1.1 General Format of Commands and Results 8.1.2 "MEASURE" Command 8.1.3 "GETCONFIGURATIONS" Command 8.1.4 "GETCONFIGIDS" Command 8.1.5 "GETTHICKNESSBOUNDS" Command 8.1.6 "STARTAUTOMATION" Command (automatic mode) 8.1.7 "STOPAUTOMATION" Command (automatic mode) 8.1.8 "TRIGGERAUTOMATIONSENSOR"...
  • Page 6: About These Instructions

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL ABOUT THESE INSTRUCTIONS PREFACE The operating manual contains information about safely operating, installing, maintaining, cleaning and repairing the device. The operating manual is part of the device and must be available to the operating and service personnel.
  • Page 7: Languages

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL LANGUAGES The Layer Check LC 1000 operating manual is available in the following languages: Language Order no. Language Order no. Language Order no. German 2395601 English 2395602 Spanish 2395605 French...
  • Page 8: Correct Use

    OPERATING MANUAL CORRECT USE DEVICE TYPE Non-contact layer thickness measuring device: Layer Check LC 1000 TYPE OF USE The thickness measuring device is suited to the non-contact measurement of layer thicknesses for the following coatings: powder lacquers before and after curing, adhesives and liquid coatings before and after drying and ceramic coatings on all materials.
  • Page 9: Warranty Conditions

    This includes, e.g., – Installation of further software – Software updates WAGNER assumes no liability for the loss of data on the embedded PC. We would recommend regularly backing up data on the embedded PC: – Saving application data: see Chapter...
  • Page 10: Identification

    Designation J. Wagner GmbH 1 Manufacturer and CE symbol D-88677 Markdorf 2 Device Type Made in Switzerland 3 Input voltage Layer Check LC 1000 Type: 4 Maximum input current Voltage: 220–240 VAC 50/60 Hz 5 Article number Current max: 10 A 6 Serial number Art.
  • Page 11: Basic Safety Instructions

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL BASIC SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS FOR THE OPERATOR Keep this operating manual at hand near the device at all times. Always follow local regulations concerning occupational safety and accident prevention. The operator shall inform the seller without delay of any safety-related events which may arise when operating the device or its accessories.
  • Page 12: Electrical Devices And Equipment

    WAGNER Service Department.If water escapes from the Layer Check, you must immediately switch it off with the mains switch, disconnect the mains plug and contact the WAGNER Service Department. Must be repaired immediately in the event of problems.
  • Page 13: Safety Instructions For The Personnel

    Only a WAGNER service center may carry out repairs and replace parts. Exception: Filter mat. Do not change or modify the device; if change is necessary, contact WAGNER. Only repair and replace parts that are listed in the chapter that are assigned to the unit.
  • Page 14: Description

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL DESCRIPTION COMPONENTS LC 1000 operating elements See Chapter 5.6. P_03487 MODE OF OPERATION The Layer Check operates on the principle of the thermal layer check. A light pulse heats the surface of the coating.
  • Page 15: Protective And Monitoring Equipment

    Operating manual in the local language see Chapter The delivery note shows the exact scope of delivery. Note: The Layer Check LC 1000 is available with monitor/PC, light barrier and lifting carriage (option): Layer Check LC 1000 Standalone (with lifting carriage)
  • Page 16: Technical Data

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL TECHNICAL DATA Description LC 1000 Power supply 1000 J Measuring distance* 5–30 cm; 2.0–11.8 inch Measuring point** Ø 2–20 mm; 0.08–0.8 inch Measuring range: Powder lacquer not cured 1–500 µm Powder lacquer cured 1–1000 µm Powder lacquer started to gel...
  • Page 17: Operating Elements And Dimensions

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL OPERATING ELEMENTS AND DIMENSIONS Front side Profile P_03488 Measurement inch Measurement inch 14.72 11.61 Ø 120 Ø 4.72 7.72 Ø 47 Ø 1.85 18.54 4.02 14.96 Rear side♠ Function On/off switch Power connection USB connection for WiFi Ethernet connection...
  • Page 18: Assembly And Commissioning

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL ASSEMBLY AND COMMISSIONING TRAINING OF ASSEMBLY/COMMISSIONING PERSONNEL The assembly and commissioning personnel must have the technical skills to safely commission the device. When assembling, commissioning and carrying out all work, read and follow the operating manuals and safety regulations for the additionally required system components.
  • Page 19: Installation And Connecting To The Mains

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 6.4.1 INSTALLATION AND CONNECTING TO THE MAINS – Install the device on a clean, sturdy, flat and horizontal surface. – Do not place any objects on or under the device. –...
  • Page 20: Assembly Of Additional Components (Example)

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL NOTICE Fingerprints and dirt on the lens! Measurement errors and device faults. Never touch the lens directly. Clean lens and measurement window according to Chapter 9.4. 6.4.2 ASSEMBLY OF ADDITIONAL COMPONENTS (EXAMPLE) 6.4.2.1 ASSEMBLY ON LIFTING CARRIAGE Follow the instructions in the lifting carriage operating manual at all times! 1.
  • Page 21: Software Environments

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 6.4.2.4 LIGHT BARRIER ASSEMBLY Follow the instructions in the light barrier operating manual at all times! Switch off voltage supply. 1. Install light barrier according to light barrier operating manual. 2.
  • Page 22: Network And Administrator Settings

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL NETWORK AND ADMINISTRATOR SETTINGS 1. Ensure that the Layer Check is correctly installed in accordance with the instructions in Chapters to 6.6. 2. Switch on device. 3. Configure Layer Check network access in accordance with Chapter 6.7.1. 4.
  • Page 23 Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 6. The IP address for the Ethernet connection can be defined in the network window (C). Notice: The sub-network addresses 192.168.139.XXX and 109.198.7.7.XXX are not permitted. P_03486 Take a note of the data so that you have it for use later on: Layer Check serial number IP address Should you lose the access data, please inform your administrator.
  • Page 24: Installing The Layer Check Desktop Client

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 6.7.2 INSTALLING THE LAYER CHECK DESKTOP CLIENT 1. Ensure that the Layer Check and Windows PC are connected using an Ethernet cable. 2. Open a web browser. Enter the IP address of the Layer Check set in Chapter 6.7.1 (e.g., "192.168.1.116") in the URL field and confirm with "Enter".
  • Page 25: Change Language

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 10. Go to: Configuration > Settings > Server P_03493 11. Enter the Layer Check IP address in the "Host or IP address" field (see Chapter 6.7.1). 12. Ensure that the connection can be established: Click on "Test server connection". If the test fails: Ensure that the PC and Layer Check are connected using an Ethernet cable.
  • Page 26: Administrator Settings

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 6.7.4 ADMINISTRATOR SETTINGS 1. Configuration > Settings > Administrator P_03494 2. Log on. Administrator password: admino041 > OK. The "Edit/delete application" field is activated. 3. Checking/removing the check from the checkbox permits/prohibits the editing and deleting of applications.
  • Page 27: Operation

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL OPERATION TRAINING THE OPERATING PERSONNEL The operating personnel must be qualified to operate the entire system. The operating personnel must be familiar with the potential risks associated with improper behavior as well as the necessary protective devices and measures. Before work commences, the operating personnel must receive appropriate system training.
  • Page 28: Measuring With The Desktop Client

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL MEASURING WITH THE DESKTOP CLIENT The Layer Check desktop client must be installed on a Windows PC in order to create applications and take manual and automated measurements. 1. Switch on Layer Check. 2.
  • Page 29: Manual Measurement

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 7.3.1 MANUAL MEASUREMENT Trigger measurement manually: 1. In the Measurement area (C) of the main window, click on button (G). 2. The result of the measurement is displayed in the defined units (e.g., µm).
  • Page 30: Automated Measurement With External Sensor

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 7.3.1.1 MANAGING BLOCKS A block is a collection of measured values. Naming, deleting and exporting blocks P_03498 2. Highlight the desired block. – Delete: Deletes the block. – Block export: Exports the block's measured values from the Layer Check on your PC. For more information about exporting data: See Chapter 7.9.
  • Page 31 Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 7.3.2.2 STARTING AND STOPPING AUTOMATIC MEASUREMENT 1. Switch to automatic mode in the header of the measuring range, in the main window: The automatic view appears: P_03600 2. Select automatic configuration (A) 3.
  • Page 32 Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 4. Start automatic measurement (C) The active automatic view appears: P_03601 5. The Trend area (F) displays the measurements. The Status line (G) displays the sensor status: Sensor signal request (polling) or measurement.
  • Page 33 Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 7.3.2.3 AUTOMATIC CONFIGURATION – Creating new automatic configuration In the automatic view (Chapter 7.3.2.2) in the "Configurations" window: – Changing existing automatic configuration Right-click on configuration name > Change configuration 2.
  • Page 34: Measurement Statistics

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 7.3.3 MEASUREMENT STATISTICS The statistics area of the main menu (see Chapter  7.3) contains statistical information about the measurement data for the block currently selected. Example of a statistical analysis of block data Meaning Average value Standard deviation...
  • Page 35: Warnings And Errors

    For settings, see Chapter 7.5.2.1. Maintenance imminent notice Device maintenance is due shortly. Inform the WAGNER (orange) Service Department to organize the maintenance cycle. Have data from "Help > About this Layer Check" to hand (see Chapter 7.3.5).
  • Page 36: System And Maintenance Information

    – 364 days after the last maintenance at the      latest. Operating the device without maintenance shortens its service life, reduces accuracy and      increases the risk of sudden failure. Contact      the WAGNER Service Department to organize the maintenance cycle.
  • Page 37: Configuring Layout Of Main Window

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 7.3.6 CONFIGURING LAYOUT OF MAIN WINDOW Optional information Display optional information in the main window (see Chapter 7.3): 1. Window > View 2. Click on the desired view > OK View Information displayed Actual Last measured value...
  • Page 38: Web Client

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL WEB CLIENT 1. Connect PC with Layer Check. Launch web client software as described in Chapter 6.7.1. The following screen appears: P_03485 2. Measure: Carry out the measurement. See Chapter 7.4.1. Monitor: Display measured values from measurements with external trigger.
  • Page 39: Monitor

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 7.4.2 MONITOR Display measured values from measurements with external trigger (either sensor or remote control software): 1. Click on "Monitor" in the web client (see Chapter 7.4). A list of all saved applications appears: P_03608 2.
  • Page 40: Settings

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 7.4.3 SETTINGS 1. Click on "Settings" in the web client (see Chapter 7.4). The settings window appears: P_03610 2. Adjust settings for depicting measurement trends with the Layer Check web client: –...
  • Page 41: Layer Check Applications

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL LAYER CHECK APPLICATIONS Calibration using reference measurements Coating processes are specified by an upper and lower layer thickness limit value (tolerance range). At least one sample with one coating at the lower limit and one sample at the upper limit of the tolerance window should be used for the calibration process.
  • Page 42 Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL P_03611 4. – Name (A): Give the new application a name. – Coating (B): Select the most suitable coating material from the drop-down menu. If there is no suitable material available, select "unknown". Use the fields for the upper and lower limit (μm) to define the tolerance range for the coating.
  • Page 43: Reference Measurement

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 7.5.2 REFERENCE MEASUREMENT P_03612 1. Position measurement object in front of the Layer Check measurement window. 2. Click on "Add…" (A). Alternatively, the measurement can be triggered by an external sensor or using a TCP command: This function can be activated with "External"...
  • Page 44 Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 7.5.2.1 DISPLAY This tab contains more settings for displaying the measured values. P_03613 Decimal places for coating thickness (A): Number of decimal places to be displayed for the coating thickness display. Definition of tolerance, warning and error ranges Measurement warning The diagram in the Trend area of the main window (see...
  • Page 45 Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL No. of measurements until error (C): Number of consecutive measurements in error range after which the measurement error range symbol is to be triggered. Requires confirmation (F): In the event of an error, an error message appears. This has to be acknowledged by the user before the measurement can continue.
  • Page 46 Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 7.5.2.2 DEVICEDEVICE P_03615 Measurement duration [ms] (A): Duration of the dynamic surface temperature measurement. The field contains a proposed value, which is determined by the choice of coating material and coating thickness range. Light energy [J] (B): Energy level of light flash.
  • Page 47 Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 7.5.2.3 EVALUATION P_03616 Substrate properties (A): "Allow variation of substrate properties": This option should be selected if you want to perform the calibration and measurement on substrates of different thicknesses (e.g., thin and thicker sheet metals).
  • Page 48 Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 7.5.2.4 LIMITS Upper and lower parameter limits for coating (A) and substrate (B) Do not change limits unless you are an expert in this field! P_03617 Layer time constant (C): Time the heat needs to penetrate the layer. Optical constant (D): States how far down the light/heat penetrates into the coating, i.e., how good the coating's absorption properties are.
  • Page 49: Calibration Report

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 7.5.3 CALIBRATION REPORT Once the calibration process is complete, the result is shown in a calibration report. P_03618 The calibration algorithm determines whether the correlation between the Layer Check and reference measurements is good and whether the Layer Check measurements are reliable. Mean deviation (A) There is too great a deviation between Layer Check and reference >...
  • Page 50 Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL Quality (B) > 94 % The quality is good. The quality is acceptable but could be improved. 90–94 % A better quality could produce a more accurate measurement. < 90 % The quality is not good.
  • Page 51 Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 7.5.3.1 APPLICATION OFFSET The correlation graph (D) can sometimes show systematic deviations between reference and Layer Check values. This can be seen with thin layers where all the calibration points are above the calibration line whereas with thick layers all the calibration points are below it (or vice versa).
  • Page 52 Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL Once the offset has been activated, the correlation graph (D) shows a smaller mean deviation (A): Meaning Shows the calibration offset (in this case 11.9 µm). P_03620 The offset allows systematic deviations between reference and Layer Check to be compensated. Such deviations may arise with rough or porous substrates/coatings in particular.
  • Page 53: Measuring Before Curing

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL MEASURING BEFORE CURING The Layer Check can be used to measure the layer thickness before curing without making contact with the coating (and therefore destroying it). This allows the Layer Check to be used to check processes and to measure process statistics.
  • Page 54: Creating Application For Measurements Before Curing

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 7.6.3 CREATING APPLICATION FOR MEASUREMENTS BEFORE CURING 1. Produce reference parts, which are to be used for the Layer Check application. These parts should cover the range to be measured by the Layer Check, e.g., the tolerance range of the coating process.
  • Page 55: Exporting Application

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 7.7.1 EXPORTING APPLICATION 1. File > Export The window shown here appears. 2. Double-click on application (A). 3. Highlight "Export application" (B). 4. Next (C). The next window appears. P_03622 5.
  • Page 56: Importing Application

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 7.7.2 IMPORTING APPLICATION 1. File > Import The window shown here appears. 2. Double-click on application (A). 3. Highlight "Import application" (B). 4. Next (C). The next window appears. P_03624 5.
  • Page 57: Importing Material File

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL IMPORTING MATERIAL FILE Material files contain settings for coating or carrier materials. Import material files as follows: 1. File > Import The window shown here appears. 2. Double-click on "Material" (A). 3.
  • Page 58: Exporting Measurement Data

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL EXPORTING MEASUREMENT DATA Export measurement data for the active application: 1. File > Export Or in the main window (see Chapter 7.3) in the Application area: The window shown here appears. 2.
  • Page 59: Remote Control

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL REMOTE CONTROL This chapter describes how to operate the Layer Check with a device, which is connected to the Layer Check via the Ethernet. This may be e.g., a PLC (e.g., Siemens S7) or a PC with third-party software.
  • Page 60: General Format Of Commands And Results

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 8.1.1 GENERAL FORMAT OF COMMANDS AND RESULTS A command line has the following format: COMMAND?ARG1=VAL1&ARG2=VAL2&...CR/LF Meaning of the elements in a command line: COMMAND Name of the command Separates a command from the arguments ARGx Name of a command argument VALx...
  • Page 61: Measure" Command

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 8.1.2 "MEASURE" COMMAND The MEASURE command triggers a Layer Check measurement. An application must be selected for the measurement. This is stated by an ID and is the only argument for the MEASURE command. Command Arguments Description...
  • Page 62: Getconfigurations" Command

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 8.1.3 "GETCONFIGURATIONS" COMMAND GETCONFIGURATIONS provides a list of all applications saved on the Layer Check. This command has no arguments. Command Arguments Description GETCONFIGURATIONS Application example GETCONFIGURATIONS<CR/LF> Result Arguments Description RES_GETCONFIGURATIONS NAME Name, which the user has given the application.
  • Page 63: Getthicknessbounds" Command

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 8.1.5 "GETTHICKNESSBOUNDS" COMMAND The GETTHICKNESSBOUNDS command provides a list of the warning and error limits for the layer thickness specified in an application. See Chapter 7.5.2.1 for more information about warning and error limits for the layer thickness. Command Arguments Description...
  • Page 64: Startautomation" Command (Automatic Mode)

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 8.1.6 "STARTAUTOMATION" COMMAND (AUTOMATIC MODE) STARTAUTOMATION is intended for using the Layer Check desktop client's automatic mode. See Chapter 7.3.2. 8.1.7 "STOPAUTOMATION" COMMAND (AUTOMATIC MODE) STOPAUTOMATION is intended for using the Layer Check desktop client's automatic mode. See Chapter 7.3.2.
  • Page 65: Getservicestatus" Command

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 8.1.12 "GETSERVICESTATUS" COMMAND Command Arguments Description GETSERVICESTATUS Result Arguments Description RES_GETSERVICESTATUS 8.1.13 "GETCOATMASTERSTATUS" COMMAND Command Arguments Description GETCOATMASTERSTATUS STATUS Is the Layer Check ready? Command to check whether a measurement can be taken. HAS_STARTUP Has a system start been run? STARTUP_WAIT_...
  • Page 66: Http

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL HTTP Triggering measurement Request URI: http://{host:port}/measurementserver/measure?configID=/{Appl-ID} Request method: POST Request headers: {Accept=[application/json], Content-Length=[0]} – {host:port} must be replaced by the TCP/IP address and port. Example: http://192.168.1.100:1234/measurementserver/ etc. – {Appl-ID} stands for the number of the application being used for the measurement. The application IDs of all applications saved in the Layer Check are stored in the list of applications along with the application names.
  • Page 67: Maintenance

    If the light source reaches 0 % or after one year since the last maintenance (even if the device has not been operating), the Layer Check must be maintained by the WAGNER Service Department. The Layer Check desktop client monitors the spare Layer Check parts. As soon as the status of a spare part becomes critical or its intended operating life is reached / exceeded, a notification to this effect appears (see Chapter 7.3.4).
  • Page 68: Software Maintenance

    Log on as the user "admin" with the password "Welcome123". 9.3.1 DIAGNOSIS When resolving problems, the WAGNER Service Department will sometimes ask for the log files. To download the Layer Check log files, proceed as follows: 1. In the main window of the Layer Check web client (see Chapter 9.3): Administrator >...
  • Page 69: Restoring Software On The Layer Check

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL 9.3.2 RESTORING SOFTWARE ON THE LAYER CHECK To reverse a software upgrade, you can restore a previously installed version of the embedded software on the Layer Check. 1. In the main window of the Layer Check web client (see Chapter 9.3): Administrator >...
  • Page 70: Measurement Window

    Layer Check VERSION 03/2018 ORDER NUMBER DOC 2395602 OPERATING MANUAL MEASUREMENT WINDOW Use compressed air free of oil to clean the measurement window of any dirt in order to ensure good performance and the reliability of the Layer Check. Stubborn dirt can be removed using a soft, fluff-free cloth and alcohol (e.g., cloth for cleaning glasses).
  • Page 71: Blank Measurement

    3. Blank measurement (G): The "Start" button (H) opens a window with the request to cover the IR lens. Place WAGNER cover for blank measurements on IR lens. Click on OK to start the blank measurement. The blank measurement serves as a reference for...
  • Page 72: Troubleshootingtroubleshooting

    WAGNER or one of our dealers will take back your used WAGNER electric or electronic equipment and will dispose of it for you in an environmentally-friendly way.
  • Page 73: Spare Parts

    Incorrect maintenance/repair! Danger to life and equipment damage. Only a WAGNER service center or a suitably trained person may carry out repairs and replace parts. Only repair and replace parts that are listed in the "Spare parts" chapter and that are assigned to the unit.
  • Page 74: Eu Declaration Of Conformity

    EN ISO 9001: 2008 Identification: EU Declaration of Conformity The EU Declaration of Conformity is enclosed with this product. If needed, further copies can be ordered through your WAGNER dealer by specifying the product name and serial number. Order number: 2395608...
  • Page 76 Order no. 2395602 Edition 03/2018 ts-powder@wagner-group.com www.wagner-group.com...

Table of Contents