Table of Contents

Advertisement

Quick Links

Version 01/2020
SprayPackE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SprayPackE and is the answer not in the manual?

Questions and answers

Summary of Contents for WAGNER SprayPackE

  • Page 1 Version 01/2020 SprayPackE...
  • Page 3: Table Of Contents

    4.1.2 A Safe Work Environment 4.1.3 Personnel Qualifications Safety Instructions for the Personnel 4.2.1 Personal Safety Equipment 4.2.2 Safe Handling of WAGNER Powder Spray Devices 4.2.3 Grounding the Device 4.2.4 Product Hoses 4.2.5 Electrical Connection Cables 4.2.6 Cleaning and Flushing 4.2.7...
  • Page 4 Scope of Delivery 5.15 Technical Data 5.15.1 Technical Data for MCE 5.15.2 Technical Data for CPE/CPE-S 5.15.3 Technical Data for Maximum SprayPackE Configuration 5.15.4 Rack (10 EPG S2) 5.15.5 EPG S2 5.15.6 EPG-Sprint X 5.15.7 Compressed Air Quality ASSEMBLY AND COMMISSIONING...
  • Page 5 SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 REPAIRS Repair Personnel Repair Notes FUNCTION TEST AFTER REPAIR WORK DISASSEMBLY AND DISPOSAL ACCESSORIES SPARE PARTS 13.1 How Can Spare Parts Be Ordered? 13.2 Spare Parts List for MCE Control Unit 13.3 Spare Parts List for Maintenance Unit 13.4...
  • Page 6: About These Instructions

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 ABOUT THESE INSTRUCTIONS PREFACE The operating manual contains information about safely operating, maintaining, cleaning and repairing the device. The operating manual is part of the device and must be available to the operating and service personnel.
  • Page 7: Languages

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 LANGUAGES The operating manual is available in the following languages: Original operating manual Language Order no. German 2397090 Translation of the original operating manual Language Order no. Language Order no. English 2397091 Russian 2397095...
  • Page 8: Terminology For The Purpose Of This Manual

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 TERMINOLOGY FOR THE PURPOSE OF THIS MANUAL Cleaning Cleaning Manual cleaning of devices and device parts with cleaning agent Flushing Internal flushing of paint-wetted parts with compressed air Personnel qualifications Trained person Is instructed in the tasks assigned to him/her, the potential risks associated with improper behavior as well as the necessary protective devices and measures.
  • Page 9: Correct Use

    Controller for automatic powder coating systems. TYPE OF USE The SprayPackE controller serves to control the EPG S2 control units for powder guns and powder conveying equipment, reciprocators and sliding tables. The device may only be operated under the following conditions: Use the device only to work with the products recommended by WAGNER.
  • Page 10: Identification

    Switzerland European Communities TYPE PLATES Wagner International AG Wagner International AG CH 9450 Altstätten CH 9450 Altstätten Designed by WAGNER in Switzerland Designed by WAGNER in Switzerland Typ / Type: Type / Typ: Serie Nr.: Serie Nr.: Serial No.: Serial No.:...
  • Page 11: Permissible Device Combinations

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 PERMISSIBLE DEVICE COMBINATIONS The following control units may be connected to the MCE: – EPG S2 – EPG S2 FM (USA Version) – EPG Sprint X – CPE – CPE-S SAFETY FEATURES Plates bearing information for the user have been attached to the work openings of the powder coating booth.
  • Page 12 SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 Wear electrostatically Wear hearing protection! conductive footwear! Wear respirator! Wear protective goggles!
  • Page 13: Basic Safety Instructions

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 BASIC SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS FOR THE OPERATOR Keep this operating manual at hand near the device at all times. Always follow local regulations concerning occupational safety and accident prevention regulations. 4.1.1 ELECTRICAL DEVICES AND EQUIPMENT Danger of electric shock! Danger to life from electric shock.
  • Page 14: A Safe Work Environment

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 4.1.2 A SAFE WORK ENVIRONMENT Danger due to dust formation! Severe or fatal injuries due to explosion danger or inhalation, swallowing or contact with the skin or eyes. The floor in the working area must be electrostatically conductive (measurements according to EN 1081 and EN 61340-4-1).
  • Page 15: Safety Instructions For The Personnel

    Danger due to noise pollution! Hearing damage due to noise pollution. Wear ear protection. 4.2.2 SAFE HANDLING OF WAGNER POWDER SPRAY DEVICES Danger due to dust formation! Do not point spray guns at people. Do not spray device parts using electrostatic equipment.
  • Page 16: Grounding The Device

    Danger due to damaged product hoses! The product hose may cause dangerous injuries. Use only an original WAGNER powder hose. Make sure that the hoses are laid only in suitable places. Hoses should not be laid in the following places under any circumstances: –...
  • Page 17: Electrical Connection Cables

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 4.2.5 ELECTRICAL CONNECTION CABLES Risk caused by improperly laid cables! Risk of injury and damage to the device. Properly lay connection cables and check them regularly. Immediately replace damaged connection cables. Ensure that no work is ever performed with a damaged connection cable.
  • Page 18: Maintenance And Repair

    Danger due to improper maintenance and repair! Danger to life and equipment damage. Only a WAGNER service center or a suitably trained person may carry out repairs and replace parts. Repair or replacement of devices or parts of devices are only allowed to be performed outside the hazard area by qualified personnel.
  • Page 19: Description

    – lights up in the event of a malfunction 5 Key switch for system release – rotary movement to the right, with spring return – start of the safety circuit 6 ON/OFF switch for the SprayPackE controller and EPG S2...
  • Page 20: Connections On Rear Side Of Mce

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 5.2.2 CONNECTIONS ON REAR SIDE OF MCE P_03708 Signal Description 1 USB 2.0 connection USB 2.0 connection for USB storage medium for software updates and saving data Close connection with cover when not in use.
  • Page 21 SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 Signal Description 10 In/Out EPG Sprint X no. 1 Release signal for high voltage and powder Signal for cleaning mode Fault message from EPG-Sprint X no. 1 11 CPE interlocking Without CPE--> short-circuit plug, order no. 2342305 With CPE -->...
  • Page 22: Front Side Of Structure, Cpe/Cpe-S

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 FRONT SIDE OF STRUCTURE, CPE/CPE-S P_03816 Designation 1 Main switch 2 CPE: closed with dummy plug 2 CPE-S: Blue illuminated button – To reset when barrier is opened...
  • Page 23: Cpe Connections On Rear Side

    Cable gland can be split for standard cable for movement devices 2 230 VAC for MCE Power supply for MCE (output) 3 Power supply for input Current input for entire SpraypackE system 3P+N+PE 230/400 V 50/60 Hz 4 Cover Not used with CPE type 5 Emergency stop output...
  • Page 24: Cpe-S Connections On Rear Side

    2 230 VAC for MCE Power supply for MCE 3 Power supply for input Current input for entire SpraypackE system 3P+N+PE 230/400 V 50/60 Hz 4 Safety door 2 Connection for safety door 2 safety switch 5 Emergency stop output...
  • Page 25: Cpe/Cpe-S Connections In Housing

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 CPE/CPE-S CONNECTIONS IN HOUSING DANGER Danger from electric current! Danger to life and equipment damage. The system may only be connected by skilled electricians. Operate according to the safety regulations, fire protection and electrotechnical regulations.
  • Page 26: Terminal Assignment

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 5.6.1 TERMINAL ASSIGNMENT Terminal block X40: Current supply 3P+N+PE 230/400 V 50/60 Hz Address Terminal Signal Description X40:1 up to 4 mm² Current supply, 1rd phase X40:2 up to 4 mm² Current supply, 2rd phase X40:3 up to 4 mm²...
  • Page 27: Can Addresses

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 CAN ADDRESSES CAN node Module type Application HU1 No. 1 Sliding table 1 HU1 No. 2 Sliding table 2 VU1 No. 1 Reciprocator 1 VU1 No. 2 Reciprocator 2 EPG S2 No. 1 Guns 1 and 2 EPG S2 No.
  • Page 28: Cpe/Cpe-S Circuit Breakers In Housing

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 CPE/CPE-S CIRCUIT BREAKERS IN HOUSING DANGER Danger from electric current! Danger to life and equipment damage. The system may only be connected by skilled electricians. Operate according to the safety regulations, fire protection and electrotechnical regulations.
  • Page 29: Components Of Spraypacke

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 COMPONENTS OF SPRAYPACKE Description Order no. MCE Master Control: 2373526 Control unit for 10x EPG S2 and 2x EPG-Sprint X, gap/height control and HU/VU movement MCE Master Control with remote service: 2394086 Control unit for 10x EPG S2 and 2x EPG-Sprint X,...
  • Page 30 SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 Description Order no. CPE blanking plate: 2395106 Is used in the rack if no CPE/CPE-S module is being used P_03713 EPG blanking plate: 2395107 Is used in the rack if no EPG S2 module is being used P_03714 Connection cable MCE–CPE 2 m...
  • Page 31 SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 Description Order no. Bridging plug for pressure sensor: 2339373 Is used if there is no pressure monitoring. Insert bridge between pins 1 and 4. P_03718 Connection for 1.5 m compressed air valve: 2395173 Valve connector type BI 11 mm...
  • Page 32: Components Of Mce

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 5.10 COMPONENTS OF MCE Description Order no. Mains cable: Europe 241270 Switzerland 241271 264626 Japan 264625 B_01065 Grounding cable for Japan 236219 EPG-S2: 2316991 EPG S2 FM (USA Version): 2343176 Universal control unit for Corona or Tribo powder spray guns or field controller One EPG S2 can control two spray guns.
  • Page 33 SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 Description Order no. CAN bus termination: 2321402 for EPG S2 and external extension P_02192 EPG-Sprint X: 2324731 Universal control unit for Corona or Tribo powder spray guns or field controller One EPG-Sprint X is required per gun.
  • Page 34 SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 Description Order no. Hose Ø 4/6 mm: 9982079 Hose connection between EPG S2/EPG-Sprint X and spray gun Hose, Ø 6/8 mm, red: 9982063 Feed air hose from EPG S2/EPG-Sprint X to powder injector Hose Ø 6/8 mm, blue:...
  • Page 35: Components Of Pulse Generator

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 5.11 COMPONENTS OF PULSE GENERATOR Description Order no. Encoder: 2335582 Hollow shaft encoder 24V/100 pulses P_01957 Bracket set for encoder 2335512 P_02188 Connection cable for encoder for MCE: P_03715 As of 20 m, the special connection cable with a 0.5 mm²...
  • Page 36: Components Of Switching Light Curtain

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 5.12 COMPONENTS OF SWITCHING LIGHT CURTAIN Description Order no. CSL710 light curtains, 10/20 mm resolution: Each order number comprises one transmitter (2) and one receiver (1) with brackets (5) and a 5 m connection cable between transmitter and receiver.
  • Page 37: Safety Functions

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 Description Order no. Assembly material included: Swivel mount BT-2R1 (2x) 2345087 P_03744 Z holder BT-2Z (2x) 2345084 P_03745 Connection cable between light curtain and MCE: To be ordered individually P_03715 The cables can be connected for longer distances.
  • Page 38: Scope Of Delivery

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 5.14 SCOPE OF DELIVERY Order no. Designation According to selected configuration The standard equipment includes: 2397262 Declaration of Conformity 2397090 Operating manual, in German see Chapter Operating manual in local language 5.15 TECHNICAL DATA 5.15.1 TECHNICAL DATA FOR MCE...
  • Page 39: Technical Data For Maximum Spraypacke Configuration

    UL listed or recognized Ambient conditions Operating temperature range 5–40 °C; 41–104 °F 5.15.3 TECHNICAL DATA FOR MAXIMUM SPRAYPACKE CONFIGURATION 2x HU 1 sliding tables, 250 W each Sliding table 2 groups with two units each 2x VU 1 reciprocators, 750 W each...
  • Page 40: Rack (10 Epg S2)

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 5.15.4 RACK (10 EPG S2) Dimensions Height 1800 mm; 70.87 inch Width 628 mm; 24.72 inch Depth 500 mm; 19.69 inch Weight 5.15.5 EPG S2 Dimensions Height 136 mm; 5.35 inch Width 270 mm; 10.63 inch Depth 200 mm;...
  • Page 41: Epg-Sprint

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 5.15.6 EPG-SPRINT X Dimensions Height 136 mm; 5.35 inch Width 270 mm; 10.63 inch Depth 200 mm; 7.87 inch Weight 5.5 kg; 12.13 lbs Electrical Mains (AC) 85–250 VAC Frequency 47–440 Hz Input power...
  • Page 42: Compressed Air Quality

    Inadequate compressed air quality! Danger of damage to the device. Operate the control units only with the prescribed compressed air quality. Only use the control unit with original WAGNER accessories. Non-observance of these conditions results in the warranty expiring. Ambient conditions If low-melting powders are used, the ambient temperature may have to be lower than 30 °C;...
  • Page 43: Assembly And Commissioning

    STORAGE CONDITIONS Until the point of assembly, the SprayPackE must be stored in a dry location, free from vibrations and with a minimum of dust. The SprayPackE must be stored in closed rooms. The air temperature at the storage location must be between -20 °C and +60 °C (-4 °F and +140 °F).
  • Page 44: Connecting The Automatic Spray Guns On The Epg S2

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 CONNECTING THE AUTOMATIC SPRAY GUNS ON THE EPG S2 Corona spray gun Corona spray gun Atomizing air CAN bus output CAN bus input Compressed air input Signal ground Mains input terminal Mains output to...
  • Page 45: Connection Diagram In The Rack

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 CONNECTION DIAGRAM IN THE RACK As a minimum development stage, an MCE with 1-10 EPG S2 can be connected. The CAN bus must be closed at the start and end. P_02568 Mains input terminal Close on last device with terminating plug (order no.
  • Page 46: Connection Diagram For Entire Spraypacke System

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 CONNECTION DIAGRAM FOR ENTIRE SPRAYPACKE SYSTEM Note: Up to 10 EPG S2 control units can be connected to the MCE. Mains input terminal P_02568 EPG S2 EPG S2 EPG S2 EPG S2 EPG-Sprint X...
  • Page 47: Pneumatic Connections In Rack

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 PNEUMATIC CONNECTIONS IN RACK P_03817 Designation 1 Digital pressure sensor 2 Air diffuser 3 Maintenance unit 4 Compressed air connection, 1" at minimum 5 Air connection for fluidization 6 Air supply connections for control units...
  • Page 48: Connection Diagram For Csl710 Light Curtain And Pulse Generator

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 CONNECTION DIAGRAM FOR CSL710 LIGHT CURTAIN AND PULSE GENERATOR A light curtain is needed in order for light/height control to work. The encoder is used to synchronize the conveyor. The connection cable (pos. 7) length 30 m, order no. 2336565 can be connected with other cables for longer distances.
  • Page 49: Grounding Of Csl710 Light Curtains

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 6.8.1 GROUNDING OF CSL710 LIGHT CURTAINS All the light curtain portal's components must be connected with the ground. The transmitter and receiver must be equipped with the grounding sliding block and must be connected to the grounded portal or nearest ground via a grounding cable.
  • Page 50: Leds On Receiver

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 6.9.2 LEDS ON RECEIVER LED 1, green LED 2, yellow Color State Description (in measuring operation) green Measuring light curtain ready (lit up permanently) (normal operation) Flashing Internal error Sensor not ready yellow All active beams free (lit up permanently) –...
  • Page 51: Meaning Of Display Symbols

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 6.9.4 MEANING OF DISPLAY SYMBOLS Symbol Description "Input" function. The selected radio button (with bright background) may be a fixed adjustment parameter or a multi-digit input field. If it's a multi-digit input field, you can use the "Selection" key to P_02482 increase the active number by one and the "...
  • Page 52 SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 6.10.1.1 FACTORY SETTING After assembly and switching a light curtain on for the first time, a "Teach" procedure is requested. If the light curtain is no longer in default setting, this can be called up again.
  • Page 53: Display" Menu

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 6.10.2 "DISPLAY" MENU 6.10.2.1 CHANGING LANGUAGE 5 basic languages are available for the display. If necessary, the language can be changed. Example: Switch to German Level 1 Level 2 Description Language English German French...
  • Page 54: Digital Io" Menu

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 6.10.2.2 ALIGNMENT OPERATION An alignment operation can be activated for correct mechanical alignment of the transmitter and receiver. Step Button Menu Description Settings Digital IO Display Language selection Operating mode Measuring operation Alignment Alignment operation...
  • Page 55 SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 Level 1 Level 2 Description IO logic Positive PNP Negative NPN IO pin2 IO function Trigger input Teach input Area output Warning output IO pin5 Inversion Normal Inverted IO pin6 Teach in height Run...
  • Page 56 SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 Step Button Menu Description Settings Main Settings Digital IO Digital outputs IO logic Adapt inputs/outputs Positive PNP Select PNP output Positive PNP Save PNP output IO logic IO pin2 Select pin2 output IO function...
  • Page 57 SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 6.10.3.3 MULTI-SEGMENT MEASURING OPERATION With the CSL710, the total scan length can be split into 4 segments. These are communicated to the control unit as 4 digital signals. These 4 segments may be selected to be equal, unequal or overlapping.
  • Page 58: Test And Diagnosis Experte Software

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 6.11 TEST AND DIAGNOSIS EXPERTE SOFTWARE These 4 segments are displayed individually on diagnosis page 4-2-5-1. Application EStop OK Light barrier 1 Conveyor running Light barrier 2 EPG Sprint error 1 Light barrier 3...
  • Page 59: Grounding

    6.12 GROUNDING The powder coating system must be perfectly grounded for safety reasons. WAGNER recommends the use of copper cable of at least 16 mm² with sufficient mechanical stability. It is important for system safety and to achieve an optimum coating, that all system components such as work pieces, conveyors, paint supply, control unit and booth or spraying stand are perfectly grounded.
  • Page 60: Grounding Of Control Units In Rack

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 6.12.1 GROUNDING OF CONTROL UNITS IN RACK P_01506 The control units are grounded with the grounding cables supplied. The grounding cable is secured to the control unit's grounding connection and the rack with the screws provided.
  • Page 61: Interlocking

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 6.14 INTERLOCKING NOTICE Danger of damage to the device! Interlock connecting plug: Pins 1 to 11 and pin 16 only carry 24 V DC control voltage and are supplied by the MCE. Applying an external voltage to these pins will destroy the MCE.
  • Page 62 SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 Signal Application Floating contact input External emergency stop buttons or fire extinguishing system. Channel 1 If using bridge, remove! Floating contact input External emergency stop buttons or fire extinguishing system. Channel 2 If using bridge, remove!
  • Page 63: Operation

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 OPERATION TRAINING THE OPERATING PERSONNEL The operating personnel must be qualified to operate the entire system. The operating staff must be familiar with the potential risks associated with improper behavior as well as the necessary protective devices and measures.
  • Page 64: Cleaning And Maintenance

    The cleaning intervals should be adapted by the operator depending on the level of use and if necessary the level of soiling. If in doubt, we recommend contacting WAGNER's specialist personnel. The valid health and safety specifications and the safety instructions provided in Chapter must be adhered to for all cleaning work.
  • Page 65: Maintenance Instructions

    Incorrect maintenance/repair! Danger to life and equipment damage. Only a WAGNER service center or a suitably trained person may carry out repairs and replace parts. Only repair and replace parts that are listed in the "Spare parts" chapter and that are assigned to the unit.
  • Page 66: Repairs

    Incorrect maintenance/repair! Danger to life and equipment damage. Only a WAGNER service center or a suitably trained person may carry out repairs and replace parts. Only repair and replace parts that are listed in the "Spare parts" chapter and that are assigned to the unit.
  • Page 67: Function Test After Repair Work

    All functions must be checked in manual and automatic mode. 11 DISASSEMBLY AND DISPOSAL We recommend having the WAGNER system disassembled by WAGNER or another specialist. Before starting disassembly, all supply media (electric current, compressed air) must be disconnected at the connection points. All powder lacquer lines must be completely emptied and then rinsed.
  • Page 68: Accessories

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 12 ACCESSORIES Order no. Designation 2321402 CAN bus termination for EPG S2/MCE (if no movement technology is connected) 2320127 CAN bus connection cable, 0.6 m; 1.97 ft 2320128 CAN bus connection cable, 2.0 m; 6.56 ft 2320129 CAN bus connection cable, 5.0 m;...
  • Page 69: Spare Parts

    Incorrect maintenance/repair! Danger to life and equipment damage. Only a WAGNER service center or a suitably trained person may carry out repairs and replace parts. Only repair and replace parts that are listed in the "Spare parts" chapter and that are assigned to the unit.
  • Page 70: Spare Parts List For Maintenance Unit

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 13.3 SPARE PARTS LIST FOR MAINTENANCE UNIT P_03741 Order no. Designation 2395065 Maintenance unit, complete 13.4 SPARE PARTS LIST FOR AIR DIFFUSER P_03742 Order no. Designation 2395066 Air diffuser, complete...
  • Page 71: Spare Parts List For Digital Pressure Sensor

    SprayPackE VERSION 01/2020 ORDER NUMBER DOC2397091 13.5 SPARE PARTS LIST FOR DIGITAL PRESSURE SENSOR P_03743 Order no. Designation 2395114 Digital pressure sensor...
  • Page 72: Declaration Of Conformity

    VDMA standard sheet 24387 Identification: EU Declaration of Conformity The EU Declaration of Conformity is enclosed with this product. If needed, further copies can be ordered through your WAGNER dealer by specifying the product name and serial number. Order number: 2397262...
  • Page 76 Order no. 2397091 Edition 01/2020 ts-powder@wagner-group.com www.wagner-group.com...

Table of Contents