AIR RESISTANCE - FACTORY INSTALLED OPTIONS/FIELD INSTALLED ACCESSORIES
Air Volume
Air Volume
LCA/LGA
cfm
L/s
036S/036H/042S/
042H/048S/060S (2 row)
800
380
1000
470
1200
565
1400
660
1600
755
1800
850
2000
945
2200
1040
2400
1135
2600
1225
2800
1320
3000
1415
AIR RESISTANCE - CEILING DIFFUSERS
Air Volume
Air Volume
2 Ends
cfm
L/s
Open
800
380
0.15 (37
1000
470
0.19 (47
1200
565
0.25 (62
1400
660
0.33 (82
1600
755
0.43 (107
1800
850
0.56 (139
2000
945
0.73 (182
2200
1040
0.95 (237
2400
1135
- - - -
2600
1225
- - - -
2800
1320
- - - -
3000
1415
- - - -
AIR THROW DATA - RTD9-65 CEILING DIFFUSER
Air Volume
cfm
L/s
1000
470
1200
565
1400
660
1600
755
1800
850
2000
945
2200
1040
AIR THROW DATA - RTD11-95 CEILING DIFFUSER
2600
1225
2800
1320
3000
1415
3200
1510
3400
1605
¡Effective throw based on terminal velocities of 75 ft. (22.9 m) per minute.
Total Resistance — inches water gauge (Pa)
Wet Indoor Coil
LCA/LGA
048H/060H/072S (3 row)
0.02 (4)
0.04 (9)
0.02 (4)
0.05 (12)
0.03 (8)
0.06 (16)
0.04 (10)
0.08 (21)
0.05 (13)
0.10 (26)
0.06 (16)
0.12 (31)
0.07 (18)
0.14 (36)
0.09 (21)
0.17 (42)
0.11 (27)
0.19 (48)
0.13 (32)
0.22 (54)
0.16 (40)
0.25 (63)
0.20 (50)
0.29 (71)
RTD9 Step-Down Diffuser
1 Side
All Ends &
2 Ends Open
Sides Open
0.13 (32)
0.11 (27)
0.16 (40)
0.14 (35)
0.20 (50)
0.17 (42)
0.26 (65)
0.20 (50)
0.32 (80)
0.20 (50)
0.40 (100)
0.30 (75)
0.50 (125)
0.36 (90)
0.63 (157)
0.44 (110)
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
¡Effective Throw
ft.
m
10-17
3-5
11-18
3-5
12-19
4-6
12-20
4-6
13-21
4-6
14-23
4-7
16-25
5-8
24-29
7-9
25-30
8-9
27-33
8-10
28-35
9-11
30-37
9-11
BLOWER DATA
LCA/LGA072H
(4 row)
0.05 (13)
0.07 (18)
0.09 (24)
0.12 (31)
0.15 (38)
0.18 (46)
0.21 (53)
0.25 (62)
0.28 (70)
0.31 (77)
0.36 (88)
0.41 (101)
Total Resistance — inches water gauge (Pa)
FD9 Flush
FD9 Flush
2 Ends
Diffuser
Open
0.11 (27)
- - - -
0.14 (35)
- - - -
0.17 (42)
- - - -
0.20 (50)
- - - -
0.24 (60)
- - - -
0.30 (75)
0.13 (32)
0.36 (90)
0.15 (37)
0.44 (110)
0.18 (45)
- - - -
0.21 (52)
- - - -
0.24 (60)
- - - -
0.27 (67)
- - - -
0.32 (80)
AIR THROW DATA - FD9-65 CEILING DIFFUSER
Air Volume
cfm
1000
1200
1400
1600
1800
2000
2200
AIR THROW DATA - FD11-95 CEILING DIFFUSER
2600
2800
3000
3200
3400
¡Effective throw based on terminal velocities of 75 ft. (22.9 m) per minute.
Page 11
Electric Heat
Electric Heat
(LCA Models)
0.04 (10)
0.06 (15)
0.09 (22)
0.12 (30)
0.16 (40)
0.21 (52)
0.25 (62)
0.31 (77)
0.37 (92)
0.43 (107)
0.50 (125)
0.58 (144)
RTD11 Step-Down Diffuser
1 Side
All Ends &
2 Ends Open
Sides Open
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
0.11 (27)
0.09 (22)
0.13 (32)
0.11 (27)
0.15 (37)
0.12 (30)
0.18 (45)
0.15 (37)
0.21 (52)
0.18 (45)
0.24 (60)
0.21 (52)
0.29 (72)
0.25 (62)
¡Effective Throw — ft. (m)
L/s
ft.
470
15-20
565
16-22
660
17-24
755
18-25
850
20-28
945
21-29
1040
22-30
1225
19-24
1320
20-28
1415
21-29
1510
22-29
1605
22-30
Economizer
0.04 (10)
0.04 (10)
0.04 (10)
0.04 (10)
0.04 (10)
0.05 (12)
0.05 (12)
0.05 (12)
0.05 (12)
0.06 (15)
0.06 (15)
0.06 (15)
FD11
FD11
Flush
Diffuser
- - - -
- - - -
- - - -
- - - -
- - - -
0.09 (22)
0.10 (25)
0.12 (30)
0.14 (35)
0.17 (42)
0.20 (50)
0.25 (62)
m
5-6
5-7
5-7
5-7
6-9
6-9
7-9
6-7
6-9
6-9
7-9
7-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lca seriesLga060Lca060