Guidelines When Connecting The Condensate Piping; Guidelines For Condensate Piping Termination - Daikin D2CNL024A1AA Installation Manual

Wall-mounted condensing boiler
Hide thumbs Also See for D2CNL024A1AA:
Table of Contents

Advertisement

Symbols:
Item
Option
Wiring depending on model
Switch box
PCB
Earth wiring
15
Wire number 15
Legend:
Part
Connector
PCB1
P1
X1A - X11
F1
X6A -X11
GV1
X12
IT1
X12
3WV1
X10
WPS1
X7
DHW FS1
X2
IE1
X12
K1
X1M
HE1
X2
NTC1
X1M
NTC2
X4
NTC3
X4
NTC4
X4
NTC5
X7
Ext2
X2M
Ext3
X2M
UPOZORENJE
External power output should only be used for optional
parts
supplied
by
manufacturer,
instructions provided within the manual of optional parts.
Failure to observe this warning will void the warranty. The
manufacturer is not responsible for any damage that may
occur this way.
4.8.7
Guidelines when connecting the
condensate piping
OPASNOST
In order to prevent escape of flue gases and so poisoning,
the condensate trap must be mounted to its place before
commissioning.
Condensate trap must be connected to a drain via an open
connection.
Precautions that should be taken about condensate piping are:
▪ Horizontal pipe runs must fall a minimum of 45 mm/metre.
▪ External piping should be kept as short as possible or thermally
insulated to prevent freezing, depending on the installation winter
climate condition.
▪ Make sure that the condensate disposal system, the piping, and
the fittings are made of acid resistant material like plastics.
D2CNL024A1AA
Wall-mounted condensing boiler
3P469346-12P – 2020.07
Description
Description
Main PCB
Boiler pump
Fan
Gas valve
Ignition transformer
Central heating / domestic hot
water diverter valve motor
Water pressure sensor
Domestic hot water flow sensor
Ionisation input
On/Off room thermostat
Overheat thermostat
Outdoor temperature sensor
Flue temperature sensor
Return temperature sensor
Flow temperature sensor
Domestic hot water temperature
sensor
Power supply cable
External power output
(230 V AC)
according
to
the
UPOZORENJE
The condensate trap outlet shall not be modified or
blocked.
OPREZ
The condensate discharge piping diameter must be large
enough so as not to restrain the condensate water flow.
UPOZORENJE
If the discharge pipe is located outdoors, take measures
against frost.
4.8.8
Guidelines for condensate piping
termination
Condensate piping can be connected to a termination in different
ways shown below:
Terminating into an internal soil and vent stack
a
b
a
Air breaker
b
Internal soil and vent stack
Terminating into an external waste system
a
Open end direct into gully, below ground but above water
level
Terminating into an external purpose made soakaway
b
4 Montaža
≥450 mm
a
a
Installation Manual
15