System Module and User Interface
Figure 35 Battery pin order
The battery temperature is estimated by measuring separate battery temperature NTC via the BTEMP line.
This is located on the main PWB, at the place where the phone temperature is closest to the battery
temperature.
Battery connector
The battery connector is a LYNX connector. It has three contacts;
• BSI (Battery size indicator)
• GND (Ground)
• VBAT (Battery voltage)
The BSI line is used to recognize the battery capacity by a battery internal pull down resistor.
Figure 36 LYNX battery connector
Charging
This phone is charged through the smaller Nokia standard interface (2.0 mm plug). The wider standard
charger (3.5 mm) can be used together with the CA-44 charger adapter.