V.3 Slaving filtration to the heat pump:
Pool filtration can be slaved to the heat pump. In this
configuration, the pool water will be filtered continuously until the
temperature set point is reached. This has several advantages:
-
the heat pump will run long enough to heat the pool to
the temperature set point, notably during high demand heating
periods;
-
the pool water will always be agreeable for swimmers at
any time of the day and not just after a filtration period.
To slave filtration to the heat pump, make a connection between
the heat pump (main terminal located inside close to the
regulator) and the timer in the filtration control panel.
The machine terminals 1 and 2 (into which wires 25 and 26 of the
regulator are inserted) must be connected one to the timer input, and one to the contactor input, A1. Wires (1.5mm
are passed though the cable gland in the machine's covering panel.
The timer and the control panel will stay in auto mode.
Every 2 hours, the machine will start up filtration to test the pool water temperature and decide whether or not it
requires heating:
if it does, the machine will run until the pool water reaches the temperature set point; once the set point is
reached filtration will either stop if the current time corresponds to a "filtration off" cycle or will remain on if the time
corresponds to a
d to be heated, the machine will shut down after 5 minutes; filtration will then either stop if the
time corresponds to a "filtration off" cycle, or will remain on if the time corresponds to a "filtration on" cycle.
Nota bene:
The first temperature sounding will take place 2 hours after slaving the filtration to the heat pump, or 2 hours after the
machine is powered up (unless a normal filtration cycle commences beforehand).