(will set it to "–") at which point the user can configure the unit to the desired
settings. If the unit is inserted with the ACK button pressed and then removed
and inserted normally (no local VistaNET or JCI connected), all previous settings
will remain.
Note: Inserting the unit into the equipment shelf without the ACK button pressed
may cause a traffic disruption in an in-service system.

Craft Interface (C.I.) Jack

The Craft Interface allows a user to connect a PC computer serial (COM) port to
the unit. The CI is an RJ-11 connector, which transmits and receives a 9600 b/s
RS-232 signal. A Microsoft-Windows-based VistaNET software and legacy DOS-
based JCI (JungleMUX Craft Interface) software allow the user to configure the
unit and monitor its status through the CI port.
Copyright  GE Multilin Inc. 2002