Spark Plug
Check the spark plug every 100 hours. Replace the
spark plug if upon inspection the electrode
or worn. Ensure the spark plug is clean. Check the gap
Ë
Ì
with a wire gauge
and reset to .76 mm or 0.030
in. if necessary. Use only Briggs & Stratton Spark
Tester (part number 19368) to check for spark.
Fuel Filter
WARNING
• Drain fuel tank or close fuel shut-off
valve before replacing fuel filter.
Otherwise, fuel can leak out creating a
fire/explosion hazard.
Valve Clearance
Check valve clearance on NG and LPG engines every
100 hours.
On gasoline engines check valve clearance every 250
hours.
Muffler/Fuel System
WARNING
• Replacement parts for muffler and fuel system
(cap, hoses, tanks, filters, etc.) must be the
same and installed in the same position as
original parts, otherwise fire can occur.
12
Note: In some areas, local law requires using resistor
Ê
spark plug to suppress ignition signals. If this engine
is burned
was originally equipped with resistor spark plug, use
same type for replacement.
Ë
Ê
When replacing fuel filter, ensure clamps are tight and
fuel flows into the same direction as the arrow marked
FLOW.