Mode 7
Function
Logging starts at defined time.
Logging stops when memory is full.
Setting
Select "START UPON START TIME" as "RECORD START CONDITION".
Define start recording date and time in field "START TIME".
Mode 8
Function
Logging starts at defined time.
Logging stops when button ENTER (7) is pressed for few seconds.
Setting
Select "START UPON START TIME" as "RECORD START CONDITION".
Define start recording date and time in field "START TIME".
Select "STOP BUTTON" as "STOP STYLE".
Mode 9
Function
Logging starts at defined time.
Logging stops after PDF report generation.
Setting
Select "START UPON START TIME" as "RECORD START CONDITION".
Define start recording date and time in field "START TIME".
Select "AFTER PDF CREATED" as "STOP STYLE".
Mode 10
Function
Logging starts and stops at defined time.
Setting
Select "START/STOP TIME" as "RECORD START CONDITION".
Define start recording date and time in field "START TIME".
Define stop recording date and time in field "STOP TIME".
Mode 11
Function
Logs data immediately and circularly.
Logging stops once the battery is depleted or "CIRCULAR LOGGING" has been replaced by another
"RECORD START CONDITION" during configuration.
Setting
Select "CIRCULAR LOGGING" as "RECORD START CONDITION".
Mode 12
Function
Logs data immediately and circularly.
Should you wish an additional stop mode you choose:
Logging stops when button ENTER (7) is pressed for few seconds
Setting
Select "CIRCULAR LOGGING" as "RECORD START CONDITION".
Select "STOP BUTTON" as "STOP STYLE".