120 Volt AC, 30 Amp Locking
Receptacle
Use a NEMA L5-30 plug with this receptacle. Connect a
3-wire cord set rated for 125 Volts AC at 30 Amps to the
plug (Figure 10).
Figure 10 — 120 Volt AC, 30 Amp, Locking Receptacle
3-Wire Cord Set
Use this receptacle to operate 120 Volt AC, 60 Hz, single
phase loads requiring up to 3,600 watts (3.6 kW) of power
at 30 Amps.The outlet is protected against overload by a
push–to–reset circuit breaker and/or a 2 pole GFCI circuit
breaker.
120 Volt AC, 20 Amp, Duplex
Receptacle
Each duplex receptacle (Figure 11) is protected against
overload by a push–to–reset circuit breaker and/or a 2 pole
GFCI circuit breaker.
BSPP Generator
NEMA L5-30
Neutral
120V
Hot
Ground (Green)
Figure 11 — 120 Volt AC, 20 Amp, Duplex Receptacle
Use each receptacle to operate 120 Volt AC, single–phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW)
at 20 Amps of current. Use cord sets that are rated for
125 Volt AC loads at 20 Amps (or greater).
12 Volt DC, 10 Amp Receptacle
This receptacle (Figure 12) allows you to recharge a 12 Volt
automotive or utility style storage battery.
Figure 12 — 12 Volt DC, 10 Amp Receptacle
This receptacle can not recharge 6 Volt batteries and can
not be used to crank an engine having a discharged battery.
See "Charging a Battery" on page 10 before attempting to
recharge a battery.This outlet is protected by a 10 Amp self
resetting circuit breaker.