7. SPEED CONTROL KNOB
0 = idle 10 = maximum speed
8. EMERGENCY STOP
Only use in case of emergency! The main switch (1) must be used for switching off.
- Press = stop
- Turn-pull out = release
With an active emergency stop, an acoustic signal will sound consisting of one bleep
every four seconds and the red indicator will blink slowly.
Starting up after engaging the emergency stop
Never release an emergency stop (reset) if you do not know who engaged
the emergency stop and why.
Release the emergency stop only when the dangerous situation has been averted!
Then press the HORN/RESET button (10) to activate the BENOMIC S for use.
9. WORK PLATFORM DOWN/UP, ROTARY SWITCH
The rotary switch can be used to lower or raise the work platform when the pipe rail trolley
is completely on the pipe rail system. The platform drops while the button is turned down
anticlockwise, and will drop the last bit slower.
Beware of people or objects in the vicinity of the scissors while lowering!
An acoustic signal will sound when the platform slowly falls in the last bit!
The scissors will rise to a maximum platform height as long as the button is turned up
clockwise. The maximum height is 3.5 metres with double scissors.
Release the button as soon as the work platform has reached the maximum height!
10. HORN / RESET
Use the horn if you want to warn someone, an acoustic signal is audible as long as the
push-button is pressed.
Use the horn / reset button (10) to activate the BENOMIC S, 'reset' after using the main
switch (1) or the emergency stop (8). After this operation, the indicator (11) will light up
green continuously when the BENOMIC S is in a safe status, it is then ready for use.
The horn 'beeper' also gives a feedback to the user if the safety status of the BENOMIC S
changes. For this, see 5.3.2.
11. THE MULTI-COLOUR INDICATOR
The indicator indicates the current status of the BENOMIC S, and is also a feedback to
the user if the safety status of the BENOMIC S changes.
For this, see 5.3.1.