Equipment Setup - Nokia NME-2A Series Tuning Instructions

Hide thumbs Also See for NME-2A Series:
Table of Contents

Advertisement

P.A.M.S.
NME–2A
Tuning Instructions
Technical Documentation

Equipment Setup

Caution: Make sure that you have switched off the PC and the printer
before making connections!
Caution: Do not connect the PKD-1 key to the serial port. You may
damage your PKD-1!
Attach the protection key PKD-1 to parallel port one (25-pin female
D-connector) of the PC. When connecting the PKD-1 to the parallel port
be sure that you insert the PC end of the PKD-1 to the PC (male side). If
you use a printer on parallel port one, place the PKD-1 between the PC
and your printer cable.
To set up equipment, connect the M2BUS adapter to the serial port
(RS-232) of the computer. In case you are using a 9-pin serial port
(normal with an AT set) use the mating adapter supplied with the M2BUS
adapter.
Attach one end of the DKH-1 modular cable to the DAU-2 PC/M2BUS
adapter and the other end to the service box. Connect one end of another
modular cable also to the service box and the other end to the phone's
system cable.
Then connect handset's spiral cable to the service box as well.
For audio testing connect the coaxial cables as follows:
- Connect both coaxial BNC - BNC cables to the connectors of service box
marked as MIC and EAR.
- Attach EAR line of coaxial cable to AF INPUT of test equipment.
- Attach MIC line of coaxial cable to MOD GEN OUTPUT of test
equipment.
The RF cable should be connected between the RF connector of the
phone and the RF connector of the test equipment.
Last, connect the system cable to the phone as well as power supply and
switch the power on to all equipments.