MICROPOINT qLabs QSV-1-CL Pro Quick Start Manual

Vet coag panel 2 liquid control

Advertisement

qLabs
®
qLabs
Vet Coag Panel 2 Liquid Control Kit Specification / Order Information
®
REF
QSV-1-CL Pro
INTENDED USE
Micropoint Biotechnologies, Inc. has optional
liquid controls for qLabs
system. The qLabs
Controls are used with qLabs
Panel 2 Test Strips to verify the qLabs
Coag Panel 2 system performance. It is
recommended that two levels of liquid controls
are used to perform the test.
WARNING AND PRECAUTIONS
1. For in vitro diagnostics use only. Do not
take internally.
Vet Coag Panel 2 Liquid Control
Quantity
qLabs
2 x 1 ml
qLabs
2 x 1 ml
For Health Care Professional Use Only
Vet Coag Panel 2
®
Vet Coag Panel 2 Liquid
®
Vet Coag
®
Name
Vet Coag Panel 2 Liquid Control Level 1
®
(For Professional Use Only )
Vet Coag Panel 2 Liquid Control Level 2
®
(For Professional Use Only)
2. Read the instructions carefully before using.
Deviations from the described procedure
may alter performance.
3. Take all necessary precautions required
when handling laboratory reagents.
Vet
®
4. Do not freeze liquid controls.
5. Do not use expired liquid controls.
6. Do not use for any purpose other than
described in the "Intended Use" section.
7. Do not interchange caps as contamination
may occur and compromise results.
Storage
18-30
C
o
18-30
C
o

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the qLabs QSV-1-CL Pro and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MICROPOINT qLabs QSV-1-CL Pro

  • Page 1 (For Professional Use Only) For Health Care Professional Use Only INTENDED USE 2. Read the instructions carefully before using. Deviations from the described procedure Micropoint Biotechnologies, Inc. has optional may alter performance. liquid controls for qLabs Vet Coag Panel 2 ®...
  • Page 2: Testing Procedures

    8. Refer to local biohazard procedures for safe Note: Please refer to the user’s manual for waste disposal. appropriate operation instructions about the test strip and the meter. REAGENTS 2. Insert the strip. Each control contains varied levels Press the power button for 2 seconds to •...
  • Page 3 button to select the “BarCode” symbol to Use the same method as indicated in step input with the built-in barcode scanner. 4 to enter the code and lot number of the Please refer to the user manual for more strip printed on the label of the foil pouch. information.
  • Page 4: Unexpected Results

    3. If the user follow all guidelines and the results are still unacceptable, please contact the local distributor or call Note: The result interface may be different, Micropoint Biotechnologies, Inc. technical depending on the software configuration. support at +86 755 86296766. 10.Finish the test.
  • Page 5: Performance Characteristics

    PERFORMANCE CHARACTERISTICS ADDITIONAL INFORMATION For additional information about this product, Within-Run PT Value S.D. please call your local distributor or call our (N=20) Mean customer service at +86 755 86296766. Level 1 17.36 0.39 2.23 Level 2 31.60 0.96 3.04 Between- PT Value S.D.
  • Page 6 Symbols Explanation In Vitro Diagnostics Name and Address of Manufacturer Temperature Limitation Lot Number Expiry Date Catalogue Number Catains Sufficient for n Tests Caution. Read Carefully.
  • Page 7 Tel +32 2 732 59 54 Fax +32 2 732 60 03 ©2015 Micropoint Biotechnologies, Inc. All rights reserved. Specifications are subject to change without notice. Printed in China. qLabs and Micropoint are registered ® ® trademarks of Micropoint Bioscience, Inc. P/N 99030545431 Rev. A1...

Table of Contents