During operation:
9. Keep this document available at the place of use.
10. Observe the safety information.
11. Operate the product in accordance with this document.
12. Operate the product in accordance with the specifications.
13. Maintain the product correctly.
14. Do not carry out any maintenance work and repairs not de-
scribed in this document without consulting the manufac-
turer first.
In cases of uncertainty:
15. Consult the nearest GEMÜ sales office.

3 Product description

3.1 Construction

Pressure switch
3
2
1
Item
Name
1*
Pressure connection
2
Housing
3
Display housing
Seals*
Isolating diaphragm*
* Media wetted

3.2 Description

The GEMÜ 3140 pressure transducer/switch is ideal for pre-
cise measurements in a wide pressure range. The sensor is
suitable for use with both highly viscous and contaminated
media and is also suitable for corrosive media due to its high-
quality material selection. A variety of electrical and mechan-
ical connections are available, depending on the version. The
LED display version boasts a rotatable 4-digit display.

3.3 Function

The GEMÜ 3140 pressure transducer converts the physical
variable pressure into an electrical signal.
www.gemu-group.com
Materials
1.4404 stainless steel or
PVDF
1.4404 stainless steel
PA 6.6
FPM or EPDM
Ceramic Al
O
(96%)
2
3

3.4 Product label

GEMÜ 3140
Product
type
Eingang:
0...10 bar abs.
Ausgang 1: IO-Link / PNP / NPN
Signal
Ausgang 2: PNP / NPN / mA / V
Versorgung: 24 V DC

4 Correct use

Danger of explosion
▶ Risk of death or severe injury.
Improper use of the product
▶ Risk of severe injury or death.
▶ Manufacturer liability and guarantee will be void.
Only use the product in accordance with the operating
conditions specified in the contract documentation and in
this document.
The product is not intended for use in potentially explosive
areas.
5 / 24
Order code
GEMÜ Gebr. Müller Apparatebau GmbH& Co. KG
Fritz-Müller-Straße 6-8
74653 Ingelfingen-Criesbach
SN: 01234567
GeMü BestNr
PIN-Belegung:
Ub+: 1 Ausgang1: 4
Ub-: 3 Ausgang2: 2
Schirm: Stecker
Connection assignment
DANGER
Do not use the product in potentially
explosive zones.
WARNING
4 Correct use
Serial
number
2018